[SENSe:]ADEMod:BWIDth:DEModulation
<Bandwidth>
[SENSe:]ADEMod:BANDwidth:DEModulation
<Bandwidth>
This command selects the demodulation bandwidth.
Parameters:
<Bandwidth>
<numeric value> (integer only)
Refer to the datasheet for a list of supported bandwidths.
*RST:
200 kHz
Default unit: Hz
Example:
//Select demodulation bandwidth
ADEM:BAND:DEM 50KHZ
Manual operation:
See
[SENSe:]ADEMod:BWIDth:RDEViation
<Deviation>
[SENSe:]ADEMod:BANDwidth:RDEViation
<Deviation>
This command defines the reference deviation for FM signals.
Prerequisites for this command
●
Select FM measurements (
Parameters:
<Deviation>
<numeric value>
*RST:
100 kHz
Default unit: Hz
Example:
//Define reference deviation
CALC:FEED 'XTIM:FMS'
ADEM:BAND:RDEV 75KHZ
Manual operation:
See
[SENSe:]FILTer:DEMPhasis[:STATe]
<State>
This command turns the deemphasis filter on and off.
You can select the time constant of the filter with
.
Prerequisites for this command
●
Select 200 kHz or 300 kHz demodulation bandwidth (
Parameters:
<State>
ON | OFF | 1 | 0
*RST:
OFF
Example:
//Turn on deemphasis filter
ADEM:BAND:DEM 300KHZ
FILT:DEMP ON