Remote Control Commands
R&S
®
EX-IQ-BOX
328
User Manual 1409.5570.32 ─ 05
[:SOURce<hw>]:EBOX:CPRI:TEST:SFP<st>:TX:DISabled?
Queries whether the interface of the breakout board and the SFP transmission line are
disabled.
Return values:
<Disabled>
0 | 1
*RST:
0
Example:
SOUR1:EBOX:CPRI:TEST:SFP:TX:DIS?
check the interface between the breakout board and the SFP
transmission line.
Response:
1
if active
0
if inactive.
Usage:
Query only
Manual operation:
See
[:SOURce<hw>]:EBOX:CPRI:TEST:SFP<st>:TX:FAULt?
Queries the error states at the SFP interfaces. If a SFP is disconnected, R&S
DigIConf
responses with
0
(error).
Return values:
<Fault>
0 | 1
*RST:
0
Example:
SOUR1:EBOX:CPRI:TEST:SFP:TX:FAUL?
check if a transmission error occured.
Response:
0
if OK,
1
if not OK
Usage:
Query only
Manual operation:
See
[:SOURce<hw>]:EBOX:CPRI:TEST:TX:REReset
<Rereset>
The command sets or clears the bit on the downlink connection which requests the RE
to reset.
Note:
This function applies to CPRI RE test mode. In this mode, the R&S
EX-IQ-BOX
acts as a CPRI REC (master). As defined in the CPRI standard specification, the CPRI
REC provides the generation of Layer 1 messages. In this section, you can simulate some
events. Use this function to see how the DUT responds to these events.
Parameters:
<Rereset>
ON | OFF
*RST:
0
Example:
SOUR1:EBOX:CPRI:TEST:TX:RER ON
request the RE to reset.
Manual operation:
See
CPRI Remote Control Commands