![Rohde & Schwarz EX-IQ-BOX Скачать руководство пользователя страница 312](http://html1.mh-extra.com/html/rohde-and-schwarz/ex-iq-box/ex-iq-box_user-manual_1477982312.webp)
Remote Control Commands
R&S
®
EX-IQ-BOX
297
User Manual 1409.5570.32 ─ 05
Parameters:
<Source>
TERMinal
TERMinal|RS232
Use the integrated terminal of R&S
DigIConf for C&M data input
or output.
This method applies to the CPRI RE test mode.
RS232
Use the RS-232-C connector for C&M data input or output.
You can use the RS-232-C interface in the CPRI RE and the CPRI
REC test mode.
*RST:
TERMinal
Example:
SOUR1:EBOX:CPRI:CM:HDLC:SOUR TERM
Enter the C&M data via the the terminal of R&S
DigIConf.
Manual operation:
See
[:SOURce<hw>]:EBOX:CPRI:CM:HDLC:STATe
<State>
The command activates and deactivates the C&M data exchange by means of HDLC
protocol (slow C&M).
Parameters:
<State>
OFF | ON
*RST:
OFF
Example:
SOUR1:EBOX:CPRI:CM:HDLC:STAT ON
switch on slow C&M.
Manual operation:
See
9.4.3 CPRI Hardware Subsystem
The hardware (
HW:
) command subsystem encloses remote-control commands for setting
hardware parameters, including the assignment to the interfaces, special settings of the
link, status information and reference clock settings.
The numeric suffix to
GPIO<dir>
distinguishes the transmission direction of the con-
nected GPIO Interfaces.
......................................................................298
.................................................................298
......................................................................299
........................................................................299
.................................................................300
..................................................................300
..................................................................300
...............................................300
...............................................301
...............................................301
.....................................................301
CPRI Remote Control Commands