User Manual 1409.5570.32 ─ 05
Parameters:
<Width>
float
Range:
1 to 65535
Example:
EBOX:CPRI:HW:GPIO:MFW:BFR 5
increases the basic frame marker output signal to 5 clock periods.
Manual operation:
See
[:SOURce<hw>]:EBOX:CPRI:HW:GPIO:MFWidth:HFRame
<Width>
Sets the frame width of the hyper frame marker output signal in clock periods.
Parameters:
<Width>
float
Range:
1 to 65535
Example:
EBOX:CPRI:HW:GPIO:MFW:BFR 2
increases the basic frame marker output signal to 2 clock periods.
Manual operation:
See
[:SOURce<hw>]:EBOX:CPRI:HW:GPIO:MFWidth:NFRame
<Width>
Sets the frame width of the node B frame marker output signal in clock periods.
Parameters:
<Width>
float
Range:
1 to 65535
Example:
EBOX:CPRI:HW:GPIO:MFW:BFR 10
increases the basic frame marker output signal to 10 clock periods.
Manual operation:
See
[:SOURce<hw>]:EBOX:CPRI:HW:GPIO<ch>:DIRection
<Direction>
Determines the transmission direction at the connected GPIO interfaces. You can indi-
vidually activate each of the three interfaces separately.
The numeric suffix to
GPIO<ch>
distinguishes between the available GPIO interfaces.