![Rohde & Schwarz EX-IQ-BOX Скачать руководство пользователя страница 306](http://html1.mh-extra.com/html/rohde-and-schwarz/ex-iq-box/ex-iq-box_user-manual_1477982306.webp)
Remote Control Commands
R&S
®
EX-IQ-BOX
291
User Manual 1409.5570.32 ─ 05
............................................................295
................................................................295
.........................................................295
...................................................................296
...................................................................296
..........................................................296
.............................................................296
................................................................297
[:SOURce<hw>]:EBOX:CPRI:CM:ETH:ACTive?
The command queries whether the interface is active.
Return values:
<Active>
OFF | ON
*RST:
OFF
Example:
SOUR1:EBOX:CPRI:CM:ETH:ACT?
check the activity of the Ethernet interface.
Response:
0
the interface is not active.
Usage:
Query only
Manual operation:
See
[:SOURce<hw>]:EBOX:CPRI:CM:HDLC:BAUDrate
<Baudrate>
Determines the number of bits to be transferred per second via the serial interface RS232.
Avvailable baudrates are: 300 | 600 | 1200 | 2400 | 4800 | 9600 | 14400 | 19200 | 28800
| 38400 | 56000 | 57600 | 115200 | 128000 | 256000 bps.
Parameters:
<Baudrate>
float
Example:
EBOX:CPRI:CM:HDLC:BAUD 2400
sets 2400 bits per second transmissioni rate.
Manual operation:
See
[:SOURce<hw>]:EBOX:CPRI:CM:ETH:BRATe?
The command queries the resulting bit rate of fast C&M data exchange. This bit rate
depends on the CPRI line bit rate and the Ethernet pointer.
Return values:
<Rate>
float
Increment: 0.01
*RST:
42240000