Numeric Measurement Modes
R&S
®
EVSG1000
75
User Manual 1178.6227.02 ─ 06
Status flags
The "STIOCPMV" value contains status flags, if applicable:
●
S
: Start (started manually)
●
T
: Triggered (externally)
●
I
: Invalid
●
O
: Overload (RF input signal too high)
●
C
: Corrected (includes RF input correction factor)
●
P
: PPS-synced
●
M
: Morse ID available
●
V
: Valid signal (ILS LOC/GP and VOR only)
For details on data logging see
Chapter 8.2, "Recording Measurement Data"
Remote commands to retrieve data:
4.1.4
ILS Localizer and Glidepath Configuration
The following settings are available for the ILS Localizer and Glidepath measurements.
Settings for recording, including trigger settings, are described in
....................................................................................75
Channel and Frequency Configuration
................................................................... 76
.............................................................................................82
Setting the Measurement Time (MTime)
.................................................................86
..................................................................................86
4.1.4.1
Configuring the Input Signal
The ILS modes can analyze RF or LF input. For details on configuring LF input mea-
surements, see
Chapter 4.1.4.5, "LF Input Configuration"
Input RF/LF
Access
: [Config]
Access VNC
: [s]
ILS Localizer and ILS Glidepath (GP) Modes