Remote Commands
R&S
®
EVSG1000
301
User Manual 1178.6227.02 ─ 06
10.2.5
Retrieving ID Results
The following commands are required to retrieve ILS Loc identifier results.
ID_DASH_LENGTH
Queries the length of time a dash is transmitted in the used Morse code in "ILS LOC"
mode
Return values:
<Time>
Dash time of ID signal
Default unit: ms
Manual operation:
See
ID_DOT_LENGTH
Queries the length of time a dot is transmitted in the used Morse code in "ILS LOC"
mode
Return values:
<Time>
Dot time of ID signal
Default unit: ms
Manual operation:
See
ID_DOTDASH_GAP
Queries the length of time that passes between a transmitted dot and a dash in the
used Morse code in "ILS LOC" mode.
Return values:
<Time>
Dot-Dash gap time of ID signal
Default unit: ms
Manual operation:
See
ID_LETTER_GAP
Queries the length of time that passes between two transmitted letters in the used
Morse code in "ILS LOC" mode.
ILS Localizer (LOC) and Glidepath (GP) Modes