Remote Commands
R&S
®
EVSG1000
290
User Manual 1178.6227.02 ─ 06
Parameters:
<Freq. Offset>
Lower frequency offset
Default unit: kHz
Return values:
<State>
READY.
The command was executed successfully.
Manual operation:
See
GS_DEMFREQS_OFFSET_UPPERFREQ?
GS_DEMFREQS_OFFSET_UPPERFREQ
<Freq. Offset>
Gets or Sets the demodulator upper frequency offset in "ILS GP" mode.
Parameters:
<Freq. Offset>
Upper frequency offset
Default unit: kHz
Return values:
<State>
READY.
The command was executed successfully.
Manual operation:
See
FILTER_GS_RESIDFM?
FILTER_GS_RESIDFM
<Bandwidth>
Defines or queries the filter type used to determine residual FM in "ILS GP" mode
Return values:
<Bandwidth>
ICAO
Filter according to ICAO specification
NARROW
Narrow filter; the DDM filters used to determine the 90
Hz/
150
Hz modulation values are used to avoid interference
between the signals
*RST:
ICAO
Example:
FILTER_GS_RESIDFM NARROW
GS_RFLF_INPUT?
<Input>
GS_RFLF_INPUT
<Input>
Configures the input source for the receiver in "ILS GP" mode.
Parameters:
<Input>
RX_IN
RF input from RX 1 In/RX 2 In connectors on the front of the
R&S
EVSG1000
ILS Localizer (LOC) and Glidepath (GP) Modes