GBAS/SCAT-I Mode (Options R&S
EVSG-K4/-K5)
R&S
®
EVSF1000
134
User Manual 1178.6410.02 ─ 05
IF Filter
The IF filter determines the bandwidth on which the measurement is performed. The
default filter bandwidth is 16.8
kHz. For GBAS/SCAT-I measurements, the complete
channel bandwidth is 25
kHz.
8.5.5
General Configuration
Access VNC
: [S]
PPS SRC
Source of the PPS signal required as a time reference
"PPS SMA"
Signal provided at the PPS In connector
"PPS GPS"
Signal provided at the RS232-GPS connector
Export xml
Exports the internal message type xml definition to a connected USB storage device
(see
Chapter 8.6, "Message XML Interface"
This is useful to create a customized definition without having to start from an empty
file.
Import xml
Imports a customized message type xml definition from a connected USB storage
device to the R&S
Chapter 8.6, "Message XML Interface"
Note that this definition is only used if you set
to "Custom".
DEC DEF
Determines which message type xml definition the decoder uses.
"Default"
Uses the definition stored internally on the R&S
EVSF1000
"Custom"
Uses the imported definition (see
Reset BER
Resets the values for the following measurement results:
●
"Bit error rate (BER) before FEC"
●
●
GBAS/ SCAT-I Measurement Configuration