![Rohde & Schwarz CMW-KM645 Скачать руководство пользователя страница 42](http://html1.mh-extra.com/html/rohde-and-schwarz/cmw-km645/cmw-km645_user-manual_1477970042.webp)
Command Reference
R&S
®
CMW-KM645
42
User Manual 1173.9740.02 ─ 04
<ResourceState>
QUE | ACT | INV
QUE:
measurement without resources, no results available
("queued")
ACT:
resources allocated, acquisition of results in progress but
not complete ("active")
INV:
not applicable because <main_state>: OFF or RDY ("inva-
lid")
Example:
See
Continuous and AF Measurements
Usage:
Query only
Firmware/Software:
V1.0.15.20
Manual operation:
See
6.4 Measurement Control Commands
The following commands specify the scope of the measurement and the filter settings.
CONFigure:FMSTereo:MEAS<i>:REPetition
.......................................................................42
CONFigure:FMSTereo:MEAS<i>:SCONdition
..................................................................... 43
CONFigure:FMSTereo:MEAS<i>:MOEXception
.................................................................. 43
CONFigure:FMSTereo:MEAS<i>:MEValuation:SCOunt:RFCarrier
........................................ 43
CONFigure:FMSTereo:MEAS<i>:MEValuation:SCOunt:RFModulation
.................................. 44
CONFigure:FMSTereo:MEAS<i>:MEValuation:SCOunt:AF
.................................................. 44
CONFigure:FMSTereo:MEAS<i>:MEValuation:AF:FILTer:DEEMphasis
.................................45
CONFigure:FMSTereo:MEAS<i>:MEValuation:AF:FILTer:LPASs
..........................................45
CONFigure:FMSTereo:MEAS<i>:MEValuation:AF:FILTer:HPASs
......................................... 45
CONFigure:FMSTereo:MEAS<i>:MEValuation:AF:FILTer:WEIGhting
....................................46
CONFigure:FMSTereo:MEAS<i>:MEValuation:AF:THDFrequency
........................................46
CONFigure:FMSTereo:MEAS<i>:MEValuation:AF:BANDpass
.............................................. 46
CONFigure:FMSTereo:MEAS<i>:MEValuation:RESult:RFSCalars
........................................ 47
CONFigure:FMSTereo:MEAS<i>:MEValuation:RESult:AFSCalars
........................................ 47
CONFigure:FMSTereo:MEAS<i>:MEValuation:RESult[:ALL]
................................................ 47
CONFigure:FMSTereo:MEAS<i>:REPetition
<Repetition>
Specifies the repetition mode of the measurement. The repetition mode specifies
whether the measurement is stopped after a single-shot or repeated continuously. Use
CONFigure:..:MEAS<i>:...:SCOunt
to determine the number of measurement
intervals per single shot.
See also: "Statistical Settings" in the R&S
CMW user manual, chapter "Remote Con-
trol"
Parameters:
<Repetition>
SINGleshot | CONTinuous
SINGleshot:
Single-shot measurement
CONTinuous:
Continuous measurement
*RST:
SINGleshot
Measurement Control Commands