1xEV-DO Signaling
R&S
®
CMW-KM8xx/-KS8xx
164
User Manual 1173.9511.02 ─ 12
Manual operation:
See
CONFigure:EVDO:SIGN<i>:NETWork:PILot:AN:ACTive
<ActiveOnAN>
Sets/gets the state of a pilot in the cell implemented by the signaling application.
The related pilot has to be pre-selected using the
command.
Parameters:
<ActiveOnAN>
OFF | ON
When set to OFF, the related carrier is physically disabled on
the cell.
Note that pilot 0 cannot be turned OFF.
*RST:
ON for pilot 0, OFF for pilots 1 and 2
Example:
See
Firmware/Software:
V2.1.20
Options:
R&S CMW-KS881
Manual operation:
See
CONFigure:EVDO:SIGN<i>:NETWork:PILot:AT:ASSigned
<AssignedToAT>
Sets/gets the assignment state of a pilot. Assigning a pilot to the AT adds the pilot to
the AT's active set (managed by the AN via TrafficChannelAssignment messages).
The related pilot has to be pre-selected using the
command.
Parameters:
<AssignedToAT>
OFF | ON
A pilot can only be assigned to the AT if it is activated on the AN
(see
CONFigure:EVDO:SIGN<i>:NETWork:PILot:AN:
Note that pilot 0 cannot be unassigned.
*RST:
ON
ON for pilot 0, OFF for pilots 1 and 2
Example:
See
Firmware/Software:
V2.1.20
Options:
R&S CMW-KS881
Manual operation:
See
CONFigure:EVDO:SIGN<i>:NETWork:PILot:AT:ACQuired?
Queries if a pilot is currently acquired by the AT, i.e. if the corresponding carrier is cur-
rently carrying traffic.
Command Reference