Rohde & Schwarz 1352.1313.12 Скачать руководство пользователя страница 5

Safety and regulatory information

R&S

®

AMN6500

5

User Manual 1352.1213.02 ─ 01

without lifting it. The foldable feet are designed to carry the weight of the LISN, but not
an extra load.

Observe the applicable national regulations and standards as part of the installation
process.

Protective ground connection

Always establish a protective ground connection before connecting the LISN to a
power source. A protective ground protects you from electrically live parts on the cas-
ing caused by high leakage currents. High leakage currents can cause electric shock,
serious personal injury or death if you touch the casing.

Only use ground cables that have a sufficient cross-section that complies with
VDE

 

0100-540

 

part 5-54 (IEC 60364-5-54).

Validate that the ground connection is safe.

The ground connection must remain until you have disconnected the LISN from the
power source.

If the LISN has an auxiliary voltage, secure the test setup with a second protective
ground. The second ground connection protects you from live parts if the ground
connection of the auxiliary cable fails.

Connecting to power

The product is an overvoltage category II product and has to be connected to a fixed
installation used to supply energy-consuming equipment such as household applian-
ces and similar loads. Electrically powered products have risks, such as electric shock,
fire, personal injury or even death.

Observe the protective measures given by VDE

 

0100-410 (IEC60364-4-41) while

working with the LISN.

Take the following measures for your safety:

Use double-insulated connecting cables with an appropriate minimum cross-sec-
tion and an appropriate minimum voltage rating.
Select the cable based on the maximum power consumption of the device under
test, the fuse rating of the building installation and the cable length. When installing
the supplied cable sockets, observe the assembly instructions and the require-
ments of the manufacturer.

By design, LISNs do not have a fuse in the measuring circuit. Therefore, you have
to make sure that the operating circuit between the power supply and the power
connector of the LISN is fused correctly.

Only use the power cable delivered with the product. It complies with country-spe-
cific safety requirements.

Only use intact cables and route them carefully so that they cannot be damaged.
Check the power cables regularly to ensure that they are undamaged. Also ensure
that nobody can trip over loose cables.

Only connect the product to a power source with a maximum fuse protection
according to the datasheet.

Safety instructions

Содержание 1352.1313.12

Страница 1: ...R S AMN6500 Two Line V Network User Manual 1352121302 Version 01 2...

Страница 2: ...y Phone 49 89 41 29 0 Email info rohde schwarz com Internet www rohde schwarz com Subject to change data without tolerance limits is not binding R S is a registered trademark of Rohde Schwarz GmbH Co...

Страница 3: ...g setup or operation procedures Where do I find safety information Safety information is part of the product documentation It warns you of potential dan gers and gives instructions on how to prevent p...

Страница 4: ...carrying the product Look up the weight in the data sheet If the product is heavy you cannot move or carry it on your own A single person can only carry a maximum of 18 kg safely depending on age gend...

Страница 5: ...a fixed installation used to supply energy consuming equipment such as household applian ces and similar loads Electrically powered products have risks such as electric shock fire personal injury or e...

Страница 6: ...ce with DIN EN IEC UL CSA 61010 1 DIN EN IEC UL CSA 60950 1 or DIN EN IEC UL CSA 62368 1 Using accessories Select accessories that are suitable for the product and the measurement task espe cially if...

Страница 7: ...nding terminal earth ground contact Chassis grounding terminal 1 3 Warning messages in the documentation A warning message points out a risk or danger that you need to be aware of The sig nal word ind...

Страница 8: ...de a standardized load impedance Defined transmission of the noise voltage generated by the equipment under test to the EMI test receiver Isolation of the test circuit from interference of the power s...

Страница 9: ...evice is damaged you should notify the responsible freight carrier immediately and retain all items of packaging in order to support your complaint The original pack aging is also useful for use when...

Страница 10: ...te LED 6 N key 7 L1 key 8 150 kHz highpass 9 Limiter toggle 10 Artificial hand connector 11 RF output connector EUT socket 1 Socket for connecting the equipment under test For country specific sockets...

Страница 11: ...ssociated LED lights up when the filter is active This key is locked when the Remote LED is lit See also Chapter 5 Remote control on page 23 Limiter 9 With this toggle key Limiter the internal protect...

Страница 12: ...y remote control The socket is an N type The output impedance is 50 3 2 Rear panel tour 1 2 3 4 5 1 Remote control connector 2 Protective grounding bolt 3 Mains connection cable 4 Reference ground rai...

Страница 13: ...ound rail 4 The ground rail that is included on the side of the device is used exclusively for con necting a reference ground A broad metal foil can be placed over it to create a low inductance connec...

Страница 14: ...u connect the V network to the power source you have to connect the R S AMN6500 to a protective ground terminal An unearthed R S AMN6500 is live Touching a live electrical device causes serious person...

Страница 15: ...t it is possible for socket connections and grounding conduc tors to become disconnected A further grounding conductor with adequate diameter must be connected between a grounding conductor connection...

Страница 16: ...neutral N must be swapped by reconnecting For country specific sockets see Chapter A Country specific connector mod els on page 27 1 The plug on the mains cable can be adapted using a country specific...

Страница 17: ...PPLY socket 1 The input is reverse voltage protected 1 4 5 Connecting to reference ground The network is connected to the PE grounding connection for the mains power supply through the mains cable but...

Страница 18: ...on the PE connection of the receiver 4 6 Connecting the equipment under test The equipment under test is connected via the socket 1 on the front of the R S AMN6500 Constant current must not exceed 16...

Страница 19: ...al standards are largely similar A detailed description is provided for example by the standard CISPR 14 1 and EN 55014 1 see also the following figure Devices under test that are not equipped with pe...

Страница 20: ...6 Test receiver B Reference ground connection M Test receiver connector P Test device connector Devices under test that have a separate ground connection and are not connected by integral grounding co...

Страница 21: ...e equipment under test If the housing is made from non conductive material metal foils are wound round the handles and a 60 mm wide foil is wound round the point on the housing that can also be grippe...

Страница 22: ...onnection cable running separately to the hand simulation 5 Two Line V Network 6 Metallic collar capable being gripped 7 Test receiver A Power supply connection B Reference ground connection low induc...

Страница 23: ...t manually prior to the remote operation is restored The settings are not saved if the device is disconnected from mains supply instead the default status L1 ON and 150 kHz HP OFF is always restored w...

Страница 24: ...Remote control R S AMN6500 24 User Manual 1352 1213 02 01 12 GND 13 TTL 5V 14 N 15 L1 18 FLT...

Страница 25: ...ve safety are not visibly damaged or even unsuitable for use in the device 1 Remove the R S AMN6500 from the mains supply 2 Let the R S AMN6500 cool down to ambient temperature 3 Check the following p...

Страница 26: ...use of natural resources and minimizing the environmental footprint of our products Help us by dis posing of waste in a way that causes minimum environmental impact Disposing electrical and electroni...

Страница 27: ...ctor models Germany as well as Australia Finland the Nether lands Norway Russia Sweden Occasionally Portugal Spain R S AMN6500 1352 1313 12 UK as well as Ireland Hong Kong Malaysia Singa pore R S AMN6...

Отзывы: