Remote control commands
R&S
®
RTM3000
742
User Manual 1335.9090.02 ─ 09
Usage:
Query only
POWer:RIPPle:RESult:NDCYcle[:ACTual]?
POWer:RIPPle:RESult:NDCYcle:AVG?
POWer:RIPPle:RESult:NDCYcle:NPEak?
POWer:RIPPle:RESult:NDCYcle:PPEak?
POWer:RIPPle:RESult:NDCYcle:STDDev?
POWer:RIPPle:RESult:NDCYcle:WFMCount?
Returns the corresponding statistic result for the negative duty cycle.
●
[:ACTual]:
current measurement result
●
AVG:
average of the long-term measurement results
●
NPEak:
negative peak value of the long-term measurement results
●
PPEak:
positive peak value of the long-term measurement results
●
STDDev:
standard deviation of the long-term measurement results
●
WFMCount:
the number of waveforms used for the displayed results
Return values:
<WaveformCount>
Usage:
Query only
POWer:RIPPle:RESult:PDCYcle[:ACTual]?
POWer:RIPPle:RESult:PDCYcle:AVG?
POWer:RIPPle:RESult:PDCYcle:NPEak?
POWer:RIPPle:RESult:PDCYcle:PPEak?
POWer:RIPPle:RESult:PDCYcle:STDDev?
POWer:RIPPle:RESult:PDCYcle:WFMCount?
Returns the corresponding statistic result for the positive duty cycle.
●
[:ACTual]:
current measurement result
●
AVG:
average of the long-term measurement results
●
NPEak:
negative peak value of the long-term measurement results
●
PPEak:
positive peak value of the long-term measurement results
●
STDDev:
standard deviation of the long-term measurement results
●
WFMCount:
the number of waveforms used for the displayed results
Return values:
<WaveformCount>
Usage:
Query only
POWer:RIPPle:RESult:PEAK[:ACTual]?
POWer:RIPPle:RESult:PEAK:AVG?
POWer:RIPPle:RESult:PEAK:NPEak?
POWer:RIPPle:RESult:PEAK:PPEak?
Power analysis (option R&S
RTM-K31)