Preparing for Use

R&S

®

RTB2000

12

Getting Started 1333.1605.02 ─ 05

All current settings are saved, and the software shuts down. Now it is safe to power
off the instrument.

3.3.3 Powering Off

Powering off is required only if the instrument must be disconnected from all power
supplies.

1. If the instrument is running, press the STANDBY key on the front panel to shut

down the instrument.

2. Switch the main power switch at the rear of the instrument to position 0.

3. Disconnect the AC power cable from the AC power supply.

Risk of losing data

If you switch off the running instrument using the rear panel switch or by disconnecting
the power cord, the instrument loses its current settings. Furthermore, program data
can be lost.
Press the Standby key first to shut down the application properly.

3.4 Replacing the Fuse

The instrument is protected by a fuse. You can find it on the rear panel between the
main power switch and AC power supply.

Type of fuse: Size 5x20 mm, 250V~, T2.5H (slow-blow), IEC60127-2/5

Risk of electric shock

The fuse is part of the main power supply. Therefore, handling the fuse while power is
on can lead to electric shock. Before opening the fuse holder, make sure that the
instrument is switched off and disconnected from all power supplies.
Always use fuses supplied by Rohde

 

&

 

Schwarz as spare parts, or fuses of the same

type and rating.

1. Pull the fuse holder out of its slot on the rear panel.

2. Exchange the fuse.

3. Insert the fuse holder carefully back in its slot until it latches.

 

 

Replacing the Fuse

Содержание 1333.1005K02

Страница 1: ...R S RTB2000 Digital Oscilloscope Getting Started Getting Started 1333 1605 02 05 Q 52...

Страница 2: ...41 29 0 Fax 49 89 41 29 12 164 Email info rohde schwarz com Internet www rohde schwarz com Subject to change Data without tolerance limits is not binding R S is a registered trademark of Rohde Schwar...

Страница 3: ...lease Notes and Open Source Acknowledgment 8 3 Preparing for Use 9 3 1 Unpacking and Checking the Instrument 9 3 2 Positioning the Instrument 9 3 3 Starting the Instrument 10 3 3 1 Powering On 10 3 3...

Страница 4: ...Contents R S RTB2000 4 Getting Started 1333 1605 02 05...

Страница 5: ...art of the product documentation It warns you about the poten tial dangers and gives instructions how to prevent personal injury or damage caused by dangerous situations Safety information is provided...

Страница 6: ...ll is 10 cm Signal levels at the input connectors are all within the specified ranges Signal outputs are correctly connected and are not overloaded Instrument damage caused by electrostatic discharge...

Страница 7: ...etting started manual The online version of the user manual provides the complete contents for immediate display on the internet Instrument help The help offers quick context sensitive access to the f...

Страница 8: ...The document is available on https gloris rohde schwarz com calcert You need the device ID of your instrument which you can find on a label on the rear panel 2 4 Release Notes and Open Source Acknowle...

Страница 9: ...material to protect the control elements and connectors Delivery contents The delivery package contains the following items R S RTB2000 digital oscilloscope R S RT ZP03 probes 2x for R S RTB2002 4x fo...

Страница 10: ...an cause the R S RTB2000 to overheat which can impair the measurement results disturb the operation and even cause damage Ensure that all fan openings are unobstructed and that the airflow perforation...

Страница 11: ...e instrument 3 3 2 Starting Up and Shutting Down To start up the instrument 1 Make sure that the R S RTB2000 is connected to the AC power supply and the main power switch on the rear panel is in posit...

Страница 12: ...loses its current settings Furthermore program data can be lost Press the Standby key first to shut down the application properly 3 4 Replacing the Fuse The instrument is protected by a fuse You can f...

Страница 13: ...1 Front panel of R S RTB2004 with 4 input channels 1 Display 2 Horizontal and vertical setup controls 3 Trigger settings action and analysis controls 4 Analog input channels 2 channels at R S RTB2002...

Страница 14: ...sures to preclude direct contact with the measurement setup Use only insulated voltage probes test leads and adapters Do not touch voltages higher than 30 V RMS or 42 V peak or 60 V DC Risk of injury...

Страница 15: ...nectors for the pattern generator P0 P1 P2 P3 The Demo 1 signal is intended for demonstration purposes PROBE COMP 7 Probe compensation terminal to support adjustment of passive probes to the oscillo s...

Страница 16: ...a Local Area Network LAN It supports up to 1 Gbit s USB type B 2 USB 2 0 interface of type B device USB for remote control of the instrument Note Electromagnetic interference EMI can affect the measur...

Отзывы: