Command Reference
R&S
®
ZNA
944
User Manual 1178.6462.02 ─ 12
Suffix:
<Ch>
.
Channel number
<PhyPt>
Physical port number
Parameters:
<Boolean>
ON - embedding active
OFF - embedding inactive
*RST:
OFF
Example:
CALC:TRAN:VNET:SEND:EMB:TND CSL
Select the Serial C, shunt L circuit model for embedding.
CALC:TRAN:VNET:SEND:EMB:PAR:R2 CSL, 2.2E+3; :
CALC:TRAN:VNET:SEND:EMB ON
Increase the resistance R2 for the Serial C, shunt L circuit model
to 2.2 kΩ and enable embedding.
Manual operation:
See
CALCulate<Ch>:TRANsform:VNETworks:SENDed:EMBedding<PhyPt>:
PARameters:DATA
<Interchange>, <arg1>
Defines a dembedding network for a single-ended port based on the given S-Parame-
ter traces.
Use
●
CALCulate<Ch>:TRANsform:VNETworks:SENDed:EMBedding<PhyPt>:
TNDefinition
to select the adequate circuit model
before
executing this com-
mand.
●
MMEMory:LOAD:VNETworks<Ch>:SENDed:EMBedding<PhyPt>
data from a Touchstone file located at the R&S
ZNA's file system.
Suffix:
<Ch>
.
Channel number
<PhyPt>
Physical port number
Setting parameters:
<Interchange>
FPORts | IPORts | SGATes
FPORts (or omitted)
Standard port sequence (network port 1 towards VNA, network
port 2 towards DUT)
IPORts | SGATes
Inverted port sequence (network port 2 towards VNA, network
port 1 towards DUT)
<arg1>
<block_data>
Content of a Touchstone file (
*.s2p
or
*.s4p
) in IEEE488.2
.
Usage:
Setting only