Command Reference
R&S
®
ZNA
1044
User Manual 1178.6462.02 ─ 12
Range:
#B00000000 to #B11111111 (for setting command),
0 to 255 (query)
*RST:
#B00000000 (0)
Example:
*RST; :OUTP1:UPOR #B00000001
Assign the channel bit value #B00000001 to the active channel
no. 1. The analyzer performs a measurement in channel no. 1,
therefore the output signal at pin 8 is switched on.
CONF:CHAN2:STAT ON; OUTP2:UPOR #B00000010
Create channel no. 2, causing it to become the active channel,
and assign the channel bit value #B00000010. The analyzer
performs no measurement in channel no. 2, therefore the output
signal is not changed.
CALC2:PAR:SDEF 'Ch2Tr1', 'S11'
Create a trace named 'Ch2Tr1' and assign it to channel 2. While
the analyzer measures in channel 2, the output signal changes
from pin 8 to pin 9.
OUTP:UPOR:ECB OFF
Reserve pin 16 to 19 for monitoring the drive ports of the ana-
lyzer.
Manual operation:
See
8.3.13
PROGram Commands
The
PROGram...
commands control external application programs that can be run on
the analyzer.
.................................................................................... 1044
................................................................................ 1045
PROGram[:SELected]:INIParameter
.............................................................................. 1046
........................................................................................ 1047
.....................................................................................1047
..........................................................................................1047
PROGram[:SELected]:EXECute
<AppName>
Starts an application process or open a file using an application available on the ana-
lyzer.
Use the comman sequence
to query the return value (see example below).
Note:
It is not possible to run several programs simultaneously. If the command
PROGram[:SELected]:EXECute ...
is sent while a previously started program is
still executed, the analyzer generates a SCPI error
–100,"Command error..."
.
Tip: Executing batch files; command prompt
When executing batch scripts or other DOS applications, the analyzer does not display
any DOS windows; the screen is left for the vector network analyzer (VNA) application.
SCPI Command Reference