Page
7
of
8
3.3. Firmware update
Roger devices are always delivered with the latest version of firmware but it can be updated by
customer. The latest version of firmware, which might offer new functionalities and/or eliminate
errors is available at
. New firmware can be uploaded to XM-8DR by means of
computer z with RogerISP software (ver. 5 or newer) and it requires communication interface
device e.g. RUD-1 connected to USB port of the computer.
Firmware update procedure
·
Place jumper on FDM pins
·
Connect XM-8DR to RUD-1 in accordance with table 5
·
Reset the device (use RESET button or switch power supply off/on)
·
Start RogerISP software and select communication port
·
In Firmware window select firmware *.hex file
·
Click Program button
·
After firmware upload, remove jumper from FDM pins and reset the device (use RESET button
or switch power supply off/on)
·
Disconnect XM-8DR from RUD-1
Table 5. Connection of XM-8DR and RUD-1
XM-8DR terminal
RUD-1 terminal
+12V
1
GND
2
IO1
5
IO2
6
4.
O
RDERING INFORMATION
Product
Description
XM-8DR-BRD
Input/output addressable expander, electronic module without enclosure
5.
P
RODUCT HISTORY
Version
Firmware
Date
Description
XM-8DR v1.0
1.0
06/2012
The first commercial version of the product