Electronic Code Locks SL2000B v1.4 and SL200S1K v1.3 EN Rev.C.doc 

2011-11-16 

 
 

 

 

Strona 8 z 13

 

 
 
 

INSTALLER Code 

All digits are “2” (2222…), the length of the code depends on the 

C10

 parameter entered 

later during Memory Reset procedure. 

USER Code no01 

All digits are “3” (3333…), the length of the code depends on the 

C9

 parameter entered 

later during Memory Reset procedure. 

All USER codes 02..55 

All USER codes no 02 -55 are blank (they doesn’t exist). 

Installation 

 

The SL2000 code lock should be mounted near the supervised door on a vertical 
piece of supporting structure. 

 

The SL2000S1k can be installed either indoor or outdoor location, SL2000B can be 

installed in indoor location only.  

 

Assure that the surface beneath of the controller’s rear panel is flat and smooth. 

 

Disconnect power supply before making any electrical connections. 

 

Once installed and electrically connected, the unit has to be properly programmed. 

 

When forgotten, MASTER and INSTALLER codes can be restored to their default 
values and then programmed again. 

 

Use separate pair of wires to supply door lock and SL2000 code lock. 

 

It is forbidden to supply the door lock directly from the DC input terminals of the 
code lock. 

 

Always add the silicon diode (e.g. 1N4007) in parallel to the door lock, note that 
diode must be located as close as possible to the door lock terminals. 

 

Do not attempt to use REL1 output for switching of voltages higher then 24V 
DC/AC. 

 
 
 

Содержание SL2000B

Страница 1: ...Roger Sp j Electronic Code Locks SL2000B v1 4 and SL2000S1K v1 3 Document version Rev C ...

Страница 2: ... two transistor outputs Bistable Switch i Bell Relay output The REL output offers one switched NO NC contact rated 1 5A 30V AC DC This output is activated each time a user code sequence is entered User code 01 55 Activation takes place after a C1C2 delay and lasts for the time specified by the C3C4 parameter Each time the RELAY switch of SL2000 lock is activated the yellow led ENTRANCE lights up B...

Страница 3: ... maximum voltage applied to it must not exceed 15VDC Normally the Aux output is used to trigger some kind of warning device e g alarm siren or buzzer Door Alarm The Door Alarm will occur when door has been opened without entering of a valid USER code door has been opened without pressing of the Exit Button door has not been closed within designated time defined by the C5C6 configuration settings O...

Страница 4: ...es of codes MASTER Code INSTALLER Code USER Codes Each type of code is dedicated for individual purpose The length of each code can be programmed during Memory Reset procedure The entry of each code must be followed by the key which is used to mark the end of the code MASTER Code The MASTER code is used to switch the SL2000 between Armed and Disarmed modes it can be 4 10 digits long INSTALLER Code...

Страница 5: ...de and program a new one If command is successfully accomplished the unit generates three series of two beeps Normally pressing is used to mark the end of the code but when pressed separately for a time longer the 0 5s it triggers Door Bell indication Programming The USER Codes The SL2000 enables programming of up to 55 different USER codes The USER codes can be managed added deleted changed only ...

Страница 6: ...to normal work it enters Armed mode Meaning of the configuration parameters C1 C10 C1C2 Specifies the time delay from a moment when USER code is entered till moment when Door Lock output will be triggered It can be programmed from 00 to 99s default 04 C3C4 Specifies the time for which Door Lock output will be activated It can be programmed from 02 to 99s default 04 C5C6 Specifies the time within d...

Страница 7: ...1 C10 digits once again The Memory Reset procedure automatically comes to an end when the last C10 digit is entered The device stores the configuration as well as all codes in a nonvolatile memory which can be reprogrammed whenever required After the Memory Reset procedure comes to an end all codes are set to factory default values see section below Default Codes Example The following digits C1 C1...

Страница 8: ...or outdoor location SL2000B can be installed in indoor location only Assure that the surface beneath of the controller s rear panel is flat and smooth Disconnect power supply before making any electrical connections Once installed and electrically connected the unit has to be properly programmed When forgotten MASTER and INSTALLER codes can be restored to their default values and then programmed a...

Страница 9: ...Electronic Code Locks SL2000B v1 4 and SL200S1K v1 3 EN Rev C doc 2011 11 16 Strona 9 z 13 ...

Страница 10: ...Electronic Code Locks SL2000B v1 4 and SL200S1K v1 3 EN Rev C doc 2011 11 16 Strona 10 z 13 ...

Страница 11: ...Electronic Code Locks SL2000B v1 4 and SL200S1K v1 3 EN Rev C doc 2011 11 16 Strona 11 z 13 ...

Страница 12: ...AC Technical Specification Parameter Value Supply 10 15 VDC Current consumption Avg 25 mA 12V DC Max 80 mA 15V DC with relay output active Anti sabotage protection Tamper NC contact 50mA 24V Environmental Class SL2000B Class II input temp 10 C 40 C relative humidity 0 75 SL2000S1K Klasa IV outdoor general temp 25 C 60 C relative humidity 0 95 Dimensions W x S x G SL2000B 105 X 104 X 30 mm SL2000S1...

Страница 13: ...67 01 26 e mail support roger pl Web www roger pl The symbol of a crossed through waste bin on wheels means that the product must be disposed of at a separate collection point This also applies to the product and all accessories marked with this symbol Products labeled as such must not be disposed of with normal household waste but should be taken to a collection point for recycling electrical and...

Отзывы: