RWL-1 Operating Manual.doc
2020-03-25
9/18
·
two 2 sec pulses when access is denied
·
lights steadily when operates in
Office mode
LED
SYSTEM
Orange
·
lights steadily in case of lock’s configuration error
·
pulses slowly in case of low battery level (batteries
must be replaced)
·
pulses every 2 sec when wireless connection is being
established in
Online mode
Power supply
RWL-1 lock is supplied from 4 pcs of AA batteries. In case of average 10 operations daily the alkaline
batteries enable 2 year functioning. Low battery level is reported to VISO management software and
additionally it is signalled locally by orange LED SYSTEM pulsing and acoustic signal generated prior to
entering standby mode.
C
ONFIGURATION
RWL-1 lock can be programmed manually or from PC computer. Manual programming enables card
management for
Offline mode
only. All configuration settings can be setup and edited using
RogerVDM program. Connection to PC requires RUD-1 interface.
Factory new lock is configured for
Offline mode
and includes 2 programming cards (ADD card and DEL
card).
Lock pulse
by default is set to 2 sec while built-in RFID reader is configured to read card serial
numbers (CSN).
Factory cards
Label
Name
Authorization
ADD
ADD programming card
New card adding to the lock
DEL
DEL programming card
Card deleting from the lock
Configuration recovery from the lock
In some circumstances it might be required to recover the configuration settings from the lock. Such
operation can be done by means of RogerVDM software. Regardless of the operating mode it is not
possible to recover communication password and card encryption keys. Recovery of the user cards
programmed in the lock’s memory, can be disabled by means of
Card codes protection
option, which
by default is set off so the card codes can be read from the lock’s memory.
Note: Once the
Card code protection
option is set, the only way to clear it is to execute memory reset
which erases entire lock’s memory.
Manual programming of the users
If the lock operates in
Offline mode
then it can be configured manually without computer. Using
manual programming it is possible to add and delete user cards. Factory new lock is configured for
Offline mode
with
Backup cards
and delivered with 2 programming cards (ADD card and DEL card).
The manual programming of the users can be used either when lock operates with
Backup cards
(50
users limit) or without
Backup cards
(100 users limit). When lock operates with 100 user limit,
programming steps related to the
Backup cards
shall be skipped.
Note: It is possible to program new ADD and DEL programming cards during memory reset
procedure.