When RUD-1 is inserted into computer USB port, short RST pins and orange LED SYSTEM 
indicator on the hub shall pulsate frequently. 

·

 

Start RogerVDM software. 

·

 

Select type of device (RWH-1), RS232 communication channel and serial port with 
connected RUD-1 interface. 

·

 

Select required settings. 

·

 

Make backup by saving settings to file (button: 

Send to File…

). 

·

 

Upload settings to the lock (button: 

Send to device

). 

·

 

In RogerVDM select Device/Disconnect. 

·

 

Short RST pins for a moment to restart device. 

 

 

Fig. 2. Connection of RWH-1 to RUD-1 interface 

Configuration parameters 

The table below includes RWH-1 configuration parameters which can be modified using RogerVDM 
software within low level configuration of device. 

Parameter 

Function 

RS485 address 

The parameter defines device address on RS485 bus. Range: 100-
115. 

RS485 encryption 

When the option is enabled then the communication between 

device and access controller is encrypted.  

RS485 encryption key 

The parameter defines key used for encryption of communication 
between device and access controller. 

RS485 communication 
timeout 

The parameter defines delay after which device will signal lost 
communication with controller. Range: 0-64s.  

Radio channels 

Parameter defines radio channels which are enabled for device. 

When radio network is created the hub automatically selects 

Содержание RWH-1

Страница 1: ...Roger Access Control System RWH 1 v1 x RACS AIR Wireless Hub Operating Manual Firmware version 1 0 Document version Rev B ...

Страница 2: ...n the same way as wired devices connected to the MC16 and their functions can be freely configured with VISO management software Multiple hubs can be connected to a single access controller forming multiple RACS 5 AIR radio networks The maximal number of hubs connected to particular controller is limited by the number of unoccupied addresses on its RS485 bus while the maximal number of all devices...

Страница 3: ...ed disturbances will affect the system and hinder its operation Wi Fi channels Channel Frequency range GHz Channel Frequency range GHz 1 2 401 2 423 2 412 8 2 436 2 458 2 447 2 2 406 2 428 2 417 9 2 441 2 463 2 452 3 2 411 2 433 2 422 10 2 446 2 468 2 457 4 2 416 2 438 2 427 11 2 451 2 473 2 462 5 2 421 2 443 2 432 12 2 456 2 478 2 467 6 2 426 2 448 2 437 13 2 461 2 483 2 472 7 2 431 2 453 2 442 1...

Страница 4: ...nfiguration parameters The table below includes RWH 1 configuration parameters which can be modified using RogerVDM software within low level configuration of device Parameter Function RS485 address The parameter defines device address on RS485 bus Range 100 115 RS485 encryption When the option is enabled then the communication between device and access controller is encrypted RS485 encryption key...

Страница 5: ...e hub Wireless network creation Devices within the same radio network must work in the same channel and be assigned with the same identifier PAN ID The selection of channel and PAN ID can be done automatically when the network is created using RogeVDM software Nevertheless it is recommended to select radio channel and PAN ID manually during low level configuration of the hub In such case all devic...

Страница 6: ...k configuration or perform a factory reset of the wireless device in accordance with its instruction manual RACS AIR tab buttons Name Function New configuration Deletes current configuration and creates new one Save configuration Uploads current configuration to hub Add devices Opens network scanning window Remove device Deletes chosen device LED indicators RWH 1 hub is equipped with 4 LED indicat...

Страница 7: ...from manufacture warranty The enclosure base must be installed according to orientation shown in fig 3 so the tamper lever could press the contact It is recommended to mount the hub on flush mounting box but it can also mounted directly on the wall with included screws Connection cable should be led through the hole in the base and connected to the screw terminals at hub front panel Connection dia...

Страница 8: ...RWH 1 Operating manual doc 2018 11 30 Page8 of 11 Fig 4 Connection between hub and controller ...

Страница 9: ... guidelines All electric cables must be connected to devices with disconnected power supply Installation near metal elements decreases wireless range If hub and access controller are not supplied from the same PSU then GND terminals of both devices should be connected Clean front panel regularly with wet cloth and mild detergent Do not clean by means of abrasive materials and such strong cleaners ...

Страница 10: ... 4GHz wireless communication range 10m in free space Environmental class according to EN 50131 1 Class II indoor general conditions temperature 10 C to 40 C relative humidity 10 to 95 no condensation IP code IP40 Dimensions H x W x D 85 x 85 x 22 mm Weight 100g Certificates CE mark Ordering information Product Description RWH 1 RS485 interface to RACS 5 AIR devices RWL 1 Wireless door lock with es...

Страница 11: ...f electric and electronic waste For detailed information on recycling contact your local authorities waste disposal company or point of purchase Separate collection and recycling of this type of waste contributes to the protection of the natural resources and is safe to health and the environment Weight of the equipment is specified in the document Contact Roger sp z o o sp k 82 400 Sztum Gościsze...

Отзывы: