MCX2D Operating Manual
12.11.2020
12/13
2. Place jumper on FDM contacts (fig. 2).
3. Restart the device by pressing RST button and TXD LED indicator will switch on.
4. Start RogerVDM program and in the top menu select
Tools
and then
Update firmware
.
5. In the opened window select device type, serial port with RUD-1 interface and path to firmware file
(*.hex).
6. Click
Update
to start firmware upload with progress bar in the bottom.
7. When the update is finished, remove FDM jumper and restart the device.
Fig. 8 Connection to RUD-1 interface (firmware update).
6.
S
PECIFICATION
Table 6. Specification
Supply voltage
13.8VDC; +/- 100mV (backup battery connected)
11-15 VDC (no backup battery)
Current
consumption
(average)
MCX2D expander: 50mA
MCX2D expander with maximal load at power outputs and maximal battery
charging current: 3.5A
Battery charging current
Configurable: 0.3A/0.6A/0.9A
Inputs
Four (DCx, DRx) parametric inputs
Transistor outputs
Four (LCKx, BELLx) outputs, each with 15V/1A DC max load
Power supply outputs
Two 13.8VDC/0.2A outputs (VOUT, AUX)
Two 13.8VDC/0.2A outputs (TML)
Two13.8VDC/1.0A outputs (VDR)
Distances
Up to 1200 m between MC16 controller and MCX expander (RS485).
Up to 1200 m between MCX expander and MCT terminals (RS485)
The total distance between controller and any terminal cannot exceed 1200m.
IP Code
IP20
Environmental
class
(according
to
EN
50133-1)
Class I, indoor general conditions, temperature: +5°C to +40°C, relative