background image

MCT82M-IO-HR Operating Manual Rev. D.doc 

  

22.06.2021 

 

8/17 

 

 

Fig. 5 MCT82M-IO-HR installation 

Содержание MCT82M-IO-HR

Страница 1: ...Roger Access Control System MCT82M IO HR Operating Manual Product version 1 0 Firmware version 1 1 18 or newer Document version Rev D ...

Страница 2: ...n key bell 3 parametric EOL inputs 2 transistor outputs 1 relay output RS485 interface Tamper protection Screw terminals Power supply The terminal requires power supply voltage in range of 11 15VDC It can be supplied from MCX2D MCX4D expander of MC16 PAC KIT from MC16 access controller e g TML output or from dedicated power supply unit The supply wire diameter must be selected in such way that the...

Страница 3: ...p The matching resistors terminators connected at the ends of transmitting lines are not required In most cases communication works with any cable type standard telephone cable shielded or unshielded twisted pair etc but the recommended cable is unshielded twisted pair U UTP cat 5 Shielded cables should be limited to installations subject to strong electromagnetic interferences The RS485 communica...

Страница 4: ... DO NOT DISTURB Red Requires programming Fig 3 Indicators and function key Note Synchronic pulsing of all four LEDs signifies lost communication with MC16 controller Buzzer The terminal is equipped with buzzer which is used to signal integral functions and it can be additionally programmed with other available functions within high level configuration VISO Inputs The terminal offers 3 general purp...

Страница 5: ...t is operated in such way that CA contacts opening is interpreted as triggering of the first input while CB opening is interpreted as triggering of the second input In VISO software DW input type is represented by two independent inputs Each can be used for different purpose and assigned with different function Parametric resistors The same values of parametric resistors are used for all inputs i ...

Страница 6: ...onfiguration VISO v2 or RogerVDM Function are assigned to outputs within high level configuration VISO Multiple functions with different priorities can be assigned to the same output at the same time Identification By default the terminal reads serial numbers CSN of MIFARE cards but it is possible to program cards with own numbers PCN in selected and encrypted sectors of card memory The use of PCN...

Страница 7: ...t panel Note MCT82M IO HR enclosure consists of front panel and back panel New device is assembled with a standard back panel but additional free of charge extended back panel is included This panel can be used when connection cable has to be hidden and no flush mounting box is available ...

Страница 8: ...MCT82M IO HR Operating Manual Rev D doc 22 06 2021 8 17 Fig 5 MCT82M IO HR installation ...

Страница 9: ...MCT82M IO HR Operating Manual Rev D doc 22 06 2021 9 17 Fig 6 MCT82M IO HR F installation ...

Страница 10: ... s power supply line and RS485 bus are connected directly to the controller The terminal can also operate with MC16 controller using MCX2D MCX4D expanders as in case of M16 PAC KIT series Fig 7 Typical connection diagram for the terminal and MC16 access controller 4 CONFIGURATION The purpose of low level configuration is to prepare device for operation in RACS 5 system In case of RACS 5 v1 system ...

Страница 11: ...onfiguration of device from VISO v2 software or remove jumper from MEM contacts to block such remote configuration Programming procedure with RogerVDM software firmware older than 1 1 30 266 1 Connect the reader to RUD 1 interface fig 8 and connect the RUD 1 to computer s USB port 2 Place jumper on MEM contacts fig 4 3 Restart the reader switch power supply off and on or short RST contacts for a m...

Страница 12: ... Yes Keypad settings Keypad activated Parameter enables deactivation of keypad Range 0 No 1 Yes Default value 1 Yes Advanced settings Stop card PIN reading when buffer full Parameter enables to reject card PIN reading by device till previous card PIN is transmitted to controller Range 0 No 1 Yes Default value 0 No Card PIN buffer timeout s Parameter defines time for card PIN storing in device buff...

Страница 13: ...r where PCN is stored Range 0 39 Default value 1 Application ID AID Parameter defines application ID number AID which indicates sector where PCN number is stored Range 0 9999 Default value 5156 Block ID Parameter defines block number where PCN is stored Range 0 2 to for sectors 0 31 and 0 14 for sectors 32 39 Default value 0 Key type Parameter defines key type used to access sector with PCN Range ...

Страница 14: ...s application key number used for file read Range 0 13 Default value 0 Key type Parameter defines encryption key type for Desfire file Range 0 TDES Native 1 TDES Standard 2 3 KTDES 3 AES128 Default value 0 TDES Native Key Parameter defines access key for Desfire file with PCN 3 KTDES key is 24 bytes 48 HEX digits TDES and AES keys are 16 bytes 32 HEX digits Manual addressing Manual addressing proc...

Страница 15: ...e jumper on MEM contacts fig 4 3 Restart the device switch power supply off and on or short RST contacts for a moment and orange LED SYSTEM will pulsate 4 Read any MIFARE card 11 times 5 Wait till device confirms reset with long acoustic signal 6 Remove jumper from MEM contacts and restart the device High level configuration VISO The purpose of high level configuration is to define logical functio...

Страница 16: ... Two IO1 IO2 open collector outputs 15VDC 150mA max load Tamper protection Enclosure opening reported to access controller Proximity cards 13 56MHz MIFARE Ultralight Classic DESFire EV1 and Plus Reading range Up to 7 cm for MIFARE Ultralight Classic Up to 4 cm for MIFARE DESFire EV1 Plus Distance 1200m maximal cable length for RS485 bus between controller and reader IP Code IP41 Environmental clas...

Страница 17: ...IO HR v1 0 06 2018 The first commercial version of product This symbol placed on a product or packaging indicates that the product should not be disposed of with other wastes as this may have a negative impact on the environment and health The user is obliged to deliver equipment to the designated collection points of electric and electronic waste For detailed information on recycling contact your...

Отзывы: