906-0002-00   Rev 9   EN

 2002

  

Rofin-Sinar UK Ltd

Safety    1 - 1

Section 1 – Safety Instructions and Precautions

1.0 General Information

It is strongly recommended that any personnel who are involved with the
installation, operation or maintenance of this laser equipment should first
read and fully understand the contents of this manual and in particular
Section 1 on Safety Instructions and Precautions.

If there are any questions or doubts on any of the safety aspects of the
equipment, then do not hesitate to contact your nearest ROFIN sales or
service office or distributor for advice before proceeding.

The installation, operation, maintenance and repair of this laser equipment
must only be carried out by ROFIN service personnel or trained staff who
have received correct instruction concerning the hazards associated with
this particular equipment.

Take extensive precautions to prevent exposure of laser energy to the eye
and skin from either direct or diffusely reflected laser beams. In addition,
precautions must be taken to prevent the hazards of fire, electrical injury
and pollution.

The information and precautions given in the following sections are
extensive but may not be complete. Laser users are advised to supplement
this information with information regarding current technological advances
as they become available.

All safety critical instructions contained within this documentation
are framed with a border and printed in bold italic typeface. In
addition, the safety warning symbol shown on the left indicates that
care should be taken when working with or on the laser equipment.

Strict compliance with the safety precautions set out and referred to in this
manual and extreme care in use are essential to minimise the chance of
accidental damage to the equipment or personal injury. ROFIN does not
accept liability for any damage or injury howsoever caused or arising.

The symbol given on the left is also used on the equipment and indicates
that the user should refer to the Equipment Operator’s Manual for more
information on the safe operation or installation of the equipment.

1.1  Laser Radiation Safety Standards

a) The European standard for the Radiation Safety of Laser Products is

EN60825. The ROFIN SC range of carbon dioxide lasers are
classified as Class 4 lasers and as such, the user should appoint a
Laser Safety Officer and should be familiar with the content of
EN60825.

Содержание SC x10

Страница 1: ...906 0002 00 Rev 9 EN 2002 Rofin Sinar UK Ltd ROFIN SC x10 Operating Manual ROFIN SC x10 OEM CO2 Slab Laser...

Страница 2: ...to the original Under law copying includes translation into another language Please note that while every effort has been made to ensure that the data given in this document is accurate the informatio...

Страница 3: ...ription of Operation of ROFIN SC x10 2 1 2 1 Laser Head Layout 2 2 2 2 Technical Specification 2 3 2 3 Cooling Water Specification 2 7 2 3 1 General Information 2 7 2 3 2 Requirements and Additives 2...

Страница 4: ...n 4 Maintenance 4 0 General Information 4 1 4 1 Optical Surfaces 4 1 4 2 Output Window 4 2 4 3 Optics Cleaning Materials 4 2 4 4 Cleaning Optical Surfaces 4 2 4 5 Purge Gas Supply 4 3 4 6 General Clea...

Страница 5: ...906 0002 00 Rev 9 EN 2002 Rofin Sinar UK Ltd ROFIN SC x10 Section 1 Safety Instructions and Precautions...

Страница 6: ...on and precautions given in the following sections are extensive but may not be complete Laser users are advised to supplement this information with information regarding current technological advance...

Страница 7: ...rein may result in hazardous radiation exposure Strict compliance with the safety precautions set out and referred to in this manual and extreme care in use are essential to minimise the chance of acc...

Страница 8: ...her applicable standards iv 89 336 EEC Electro Magnetic Compatibility Directive EN50082 2 EMC immunity for industrial environments EN55011 EMC emissions for equipment that include RF generators 1 4 Tr...

Страница 9: ...ocal point the laser beam rapidly diverges causing dissipation of the energy density or intensity of the beam The Laser Aperture is clearly marked with a label stating LASER APERTURE Avoid eye or skin...

Страница 10: ...ld be used to automatically disable the laser when the guard door is opened In addition the door interlock circuit should be designed or configured such that operator intervention is required before t...

Страница 11: ...carbonate Standard materials handbooks or the manufacturer of the material should be contacted before attempting to process such materials with a laser In addition fume extraction is recommended for r...

Страница 12: ...serviceable parts within the protective housing and does not contain any access panel with Safety Interlocks within the meaning of EN60825 section 4 3 ii Laser Radiation Emission Warning Lamp It is t...

Страница 13: ...that the laser output should not be restored automatically if the mains power fails or an interlock is broken and then reset The end user must provide for a manual restart mechanism under these circum...

Страница 14: ...906 0002 00 Rev 9 EN 2002 Rofin Sinar UK Ltd ROFIN SC x10 Section 2 General Description...

Страница 15: ...9 by a radio frequency voltage 5 10 The rear mirror 7 and output mirror 3 form the optical resonator The laser beam 1 is produced within the resonator and is emitted through a window 2 Water 4 6 is u...

Страница 16: ...r directs the laser beam towards an angled spherical reflective element which corrects the shape of the beam to make it round and also focuses the beam into the spatial filter The spherical mirror the...

Страница 17: ...s Peak Power 60 230 Watts Power Stability 7 Pulsed Frequency up to 10kHz for full modulation depth higher frequencies for quasi CW operation Pulse Energy 5 230mJ Pulse Rise Fall Time 45 s External Dim...

Страница 18: ...N 2002 Rofin Sinar UK Ltd General Description 2 4 Input VA 1 7kW max External Dimensions mm 227 5 L x 371 0 W x 80 0 H Weight 9 5kg Figure 2 2 1 External Dimensions for the Laser Head note all dimensi...

Страница 19: ...adius 400mm for a moving cable RF connector torque setting 4Nm 2 95 ft lb Standard Length depends on customer order In general specific lengths are available from approximately 1 to 10m For more infor...

Страница 20: ...05 0077 00 note all dimensions in millimetres f Coolant Requirements Heat Load 2000 Watts max Coolant flow rate 4 litres min minimum Coolant temperature 19 25o C 1o C from coolant setting Coolant pres...

Отзывы: