Cerber
®
C41
H
OOKUP
I
NSTALLATION
& P
ROGRAMMING
M
ANUAL
10
A
RMING
Before arming the system, make sure that all protected doors and windows
are closed.
If the System LED is lit, check the following
:
- the alarm memory ([*][5] command). If there are alarms in the memory, they
will be cleared when arming the system.
- bypassed zones ([*][3] [Access code] command). Make sure that all zones
displayed as being bypassed are intentionally bypassed.
- system trouble ([*][4] command). If there is trouble with the battery or the
AC power, fix them before arming.
If "READY" LED is not lit
, then one or more zones are opened. One cannot
arm the system unless "Ready" LED is lit.
To arm the system, introduce a 4 digit access code. Whenever a key is
pressed, the keypad buzzer will emit a short beep.
After pressing the access code, the "Armed" LED will turn on and the keypad
buzzer will emit 6 beeps.
If the access code is not correct, the keypad buzzer will sound a long beep.
Press the [#] key, and then press the access code again.
After pressing the access code and the "Armed" LED was lit, exit the
protected area through the Entry/Exit zone before the Exit time was over.
After the Exit time was over, all LEDs will be off except the "Armed" LED.
The default Exit time is 120 seconds (see section [03]).
O
THER
A
RMING
M
ODES
Q
UICK
-A
RM
[*] [0]
This function will be used by someone who doesn't own an access code.
Arming will be done by pressing the sequence [*][0]. Next, the user should
leave the protected area before Exit time was over. After the Exit time was
over, the whole system will arm and the "Armed" LED will stay lit.
INSTANT STAY A
RMING
[*] [1] [A
CCESS
C
ODE
]
This arming mode is
used for perimetral protection. Thus, the user can stay inside the protected
area (i.e.: arming the panel at night while staying home).