Rodix FC-42-DC Plus Скачать руководство пользователя страница 3

1

8

8

FEEDER BOWL/HOPPER INTERLOCK

12

9

SWITCH

C)

LOW VOLTAGE INPUT SWITCHING

FC-90 PLUS SERIES

OFF/ON CONTROL GUIDE

(DC Voltage from PLC or FC-90 Plus)

J1

7

11

A)

12

10

11

5

FC-40 PLUS SERIES TERM STRIP TB-2, INPUT

8

B)

TERM STRIP TB-2, OUTPUT

10

5

FC-40 PLUS SERIES TERM STRIP TB-2

12

+

OFF/ON CONTROL

FC-40 PLUS SERIES TERM STRIP TB-2

11

-

10-30 VDC INPUT VOLTAGE

See section 6 of the Application Note for more

details on the REMOTE OFF/ON CONTROL guide.

10

6

6

5

LOW CURRENT

SWITCH

7

9

7

9

6

3

PADDLE

2

So

ft

TRANSFORMER

60 Rev

Sig.

1

SIG

cw

-

1/8W MIN

100K

+

CONTROL

MAIN

POT

POWER

Mi

n

Ma

x

11

6

8

8

12

60

SW3

SW5

Ex ter nal

-

JUMPER

+

SW4

5

2

11

9

4

7

7

10

3

12

6

5

1

10

9

LINE VOLTAGE

LOAD

G

TRIAC

TERM. STRIP

P/N 24-210

AC HOT

(SMALL)

CHASSIS

A1

FC-40 PLUS

OUTPUT POWER

FUSE

+

+

GATE

Pot Input

AUX FEATURE

AC COMMON

120

TB2

TERM. STRIP

TB2

J1

A2

(TALL)

4-20mA

+

TB1

-

-

S1

GND

TB1

Or
 #

1

4

Wh

 #

1

4

Bl

 #

1

4

Bl #14

Bl

 #

1

4

Vi

 #

2

0

Wh

 #

1

4

Wh

 #

2

0

D ir ec t

R UN

RUN

In ter loc k

H1

-

+

 

-

-

+

 

Bl #14

Wh #14

Wh #14

Bl #14

So

ft

TRANSFORMER

60 Rev

1

Sig.

SIG

cw

-

100K

+

1/8W MIN

CONTROL

MAIN

POT

POWER

Mi

n

Ma

x

11

6

8

8

12

60

Ex ter nal

SW3

SW5

-

JUMPER

+

SW4

5

9

2

7

11

10

4

12

7

6

3

5

1

10

9

LINE VOLTAGE

LOAD

COM

TRIAC

G

TERM. STRIP

P/N 24-210

AC HOT

(SMALL)

A1

FC-40 PLUS

OUTPUT POWER

FUSE

CHASSIS

+

+

GATE

Pot Input

GND

AUX FEATURE

AC COMMON

120

HOT

TB2

TERM. STRIP

TB2

A2

(TALL)

4-20mA

J1

+

TB1

-

INPUT POWER

S1

-

TB1

Or
 #

1

4

GND

Wh

 #

1

4

Bl

 #

1

4

Bl #14

Bl

 #

1

4

Vi

 #

2

0

Wh

 #

1

4

Wh

 #

2

0

D ir ec t

R UN

In ter loc k

RUN

H1

-

+

 

-

-

+

 

Wh #14

Bl #14

Bl #14

Wh #14

Bl #14

Bl #14

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 
 
 
 
 
 

RODIX INC. 

FEEDER CUBE

 

FC-40

 

Plus Series

 

WIRING DIAGRAM 

MODEL 

 

INPUT VAC 

AMPS 

OUTPUT VDC 

FC-42-DC 

Plus

    120 VAC            10/5 

   0-90/130

 

RODIX, INC.

 

2316 23

rd

 Ave., Rockford, IL  61104 

Toll Free (800) 562-1868, FAX (815) 316-4701

 

Email [email protected] 

www.rodix.com 

 

FC-42-DC Plus 24-210.doc 

 3/15/2012  Page 3 

Содержание FC-42-DC Plus

Страница 1: ...output power is controlled by the MAIN CONTROL DIAL It is a logarithmic tapered power out curve non linear that spreads the power broadly across the MAIN CONTROL DIAL The logarithmic taper power curve helps to give maximum Fine Control over the output speed of the vibratory feeder When very precise adjustment of the MAIN CONTROL DIAL is needed increase the MIN trimpot setting and or decrease the M...

Страница 2: ...t from RODIX the FC 40 Plus Advanced Application Note 24 210 24 211 11 STATUS LEDs When any of the inputs are active the associated LED will turn ON When the RUN input conditions are met the RUN LED will turn ON See section 6 and the wiring diagram s ON OFF Control Guide for more information on how to satisfy the RUN conditions WARNING Fuses should be replaced with a Bussman ABC or Littelfuse 3AB ...

Страница 3: ... Input AUX FEATURE ACCOMMON 120 TB2 TERM STRIP TB2 J1 A2 TALL 4 20mA TB1 S1 GND TB1 Or 14 Wh 14 Bl 14 Bl 14 Bl 14 Vi 20 Wh 14 Wh 20 D irect R UN RUN In terlock H1 Bl 14 Wh 14 Wh 14 Bl 14 Soft TRANSFORMER 60 Rev 1 Sig SIG cw 100K 1 8WMIN CON TROL MAIN POT POWER Min Max 11 6 8 8 12 60 External SW3 SW5 JUMPER SW4 5 9 2 7 11 10 4 12 7 6 3 5 1 10 9 LINE VOLTAGE LOAD COM TRIAC G TERM STRIP P N 24 210 AC...

Страница 4: ...lutions for Electrical Noise 1 Use shielded wires for all I O Input Output signals The I O signals may include 4 20mA input Run input Sensor input 0 5VDC input Interlock input or AUX output The shield drain wire should be tied to the chassis in the Rodix control The drain wire should be kept shorter than 2 Please see the enclosed picture Example of a drain wire termination 2 Never run I O signal w...

Отзывы: