background image

 

 

File No. E183233

 

RODIX INCORPORATED 

TOLL FREE (800) 562-1868, FAX (815) 316-4701 

E-mail [email protected] 

rodix.com

 

 

 

 
 
 
 
 

 

FEEDER CUBE ® 

 

 

VF-3-OR, P/N 121-000-0772* and 121-200-0772 

 

 

* Includes CFR vibration sensor P/N 123-215 

 

 

OIL RESISTANT MODEL 

 

 

IMPORTANT:  APPLICATION NOTE   

 

 

 

  

              

 

 

Input: 85 - 264 VAC, 50/60 HZ. 
Single Unit Fuse Size: 5 AMPS 
Output: 0 - 120/240 VAC 
Maximum output voltage matches input voltage 

 

 

Output Frequency: 5 - 300Hz 

 

 

Rated Output Current:  3 Amps at 120V or 1.5 Amps at 240V 
Rated for IP54 environment 
UL rated for Type 5 environment 

 

 

Model Information:  The Autotune Series of Variable Frequency Feeder Cubes® generates an output frequency for feeding 
that is independent from the power line frequency.  An optional vibration sensor, P/N 123-215, can be used to maintain the 
vibratory feeder at a constant feed rate.  The start/stop operation of the output can be controlled with an optional parts 
sensor.  For more information on this control, refer to the enclosed Adjustments and Set Up pages. 

 
 

 

 
 

 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

© 2005, 2017 RODIX 

INC

 

 

 

 

 

 

 

 

5/4/2017  Page 1

Содержание Autotune Series

Страница 1: ...Rated Output Current 3 Amps at 120V or 1 5 Amps at 240V Rated for IP54 environment UL rated for Type 5 environment Model Information The Autotune Series of Variable Frequency Feeder Cubes generates an...

Страница 2: ...Bl 14 Out LCD Contrast Br Bl 14 Out Danger Shock Hazard E ACCEPTS BOTH OPTIC AND PROX SENSORS NPN OR PNP Analog Gnd 11 7 MASTER CONTROL SM312FP1H OPTICS INPUT 3 Bl OPTIC SENSOR 1 RUN 2 R27 High Voltag...

Страница 3: ...nnecting TB1 L2 to the L2 fuse holder Remove the terminal end of the wire connecting the L2 fuse to the power switch and connect it to TB1 L2 1 Parts Sensor Input Photo sensor or Proximity Switch Conn...

Страница 4: ...or below the minimum power setting level The amplitude power setting is displayed in the following manner A 50 0 8 Limiting The Maximum Output Of Control The Max Amplitude setting can be adjusted to...

Страница 5: ...g is enabled the normal display menu will show a bold F When is shown in bold the control is locked onto the resonate frequency of the feeder C The frequency can be adjusted with an analog 0 10 volt i...

Страница 6: ...n will put the original factory settings into the memory 23 Language The run display and programming menus can be set to display in English Spanish Espa ol French Fran ais or German Deutsch 24 Over Cu...

Страница 7: ...nate control Steps to Interlock an FC 40 Plus Series to a VF Series Control 1 Add a wire from terminal 2 of the VF master control to TB2 11 of the subordinate control 2 Add a wire from terminal 3 of t...

Страница 8: ...r Resets Control to Factory Default Settings Shown in bold Language Pick Language English Espa ol Spanish Fran ais French Deutsch German Normal Display Message Priority The normal operating display sh...

Страница 9: ...ensor at least 20 minutes to cure before operation Note It takes 72 hours for the adhesive to fully cure at 70 F Alternatively 8 or M4 screws can be used to mount the sensor to the feeder The mounting...

Страница 10: ...f a nearby noise source Solutions for Electrical Noise 1 Use shielded wires for all I O Input Output signals The I O signals may include 4 20mA input Run input Sensor input 0 5VDC input Interlock inpu...