22
22
Z21
®_
Detector X16
Configuration via button
Connect the Z21
®
- Detector X16 to the R-Bus and supply track voltage of the control panel to the track
inputs P and N of the Z21
®
- Detector X16.
The blue "Status" LED flashes briefly and does not light up permanently until you have connected the
Z21
®
- Detector X16 to the R-Bus. Press the programming button on the Z21
®
- detector X16 for at least 1
second; the white program LED starts to flash. Activate a magnet article with the address of your choice
within the next minute. The magnet article can be activated using the Z21
®
App or another input device
such as the MULTIMAUS. The address has been accepted by the Z21
®
- detector X16 after the white pro-
gram LED has stopped flashing.
Configuration via pseudo CV address
Connect the Z21
®
- detector X16 to the Z21
®
via the R-Bus and provide the track inputs
P
and
N
on the
Z21
®
- detector X16 with the track voltage from the control centre.
If you have correctly connected the Z21
®
- Detector X16, you can either use the configuration software
"Z21
®
Maintenance Tool" in the CV programming tab, the WLAN-MULTIMAUS
®
, the MULTIMAUS
®
or the
multiMAUS
pro
(if using a multiZENTRALE
pro
) in the PROGRAMMING menu | Configure CV CHANGE via the
pseudo
"loco address" 9819
. If you happen to own a real locomotive with this address, please remove
it from the track before.
Before programming a CV, the programming button on the Z21
®
- Detector X16 must be pressed for at
least 1 second (but no more than 2 seconds). The white LED then flashes for a maximum of one minute to
show that the module is waiting for CV programming. As soon as a CV has been received or the waiting
time has elapsed without receiving a CV, the programming mode is ended and the white LED goes out.
CVs for pseudo CV programming
CV
Description
Note
Factory setting
99
Module address
0 = adress 1
1…20 = adress 1…20,
21…255 = invalid (address not being changed)
1 (adress 1)
100
Current threshold
0 = 0,5 mA, 1 = 1mA,
2 = 2mA, ..., 70 = 70mA, 71…255 = 70mA
4 (4mA)
101
Response time
0 = 10ms, 1 = 10ms, 2 = 20ms, ..., 16 = 160ms,
17…255 = 160ms
1 (10ms)
102
Fall time
0…255 = 0…2550ms
10 (100ms)
8010819920 .indd 22
07.01.2019 09:38:58