REMEDY INSTRUCTIONS – iRV TANK MONITOR
Page 3 of 4
V1.25H BRAIN BOX (BLACK BOX) SOFTWARE UPGRADE WITH SERIAL NUMBER STARTING WITH 1606XXX - FIRST BATCH UPGRADE
V2.1H BRAIN BOX (BLACK BOX) SOFTWARE UPGRADE WITH SERIAL NUMBER STARTING WITH 1608XXX - SECOND BATCH UPGRADE
SOFTWARE UPDATE FOR RSB66
STEP 2: SOFTWARE UPDATE
A. Plug the AC adapter into an 110V-120V outlet, then plug it
into the Program Module;
B. The arrow on the 10 Pin Connector should point towards
you while you plug it into the RSB66 (black box) unit;
C. A Blue Light and a Red Light (on the module right) should
power-on, indicating steps A and B are completed;
D. Short Press the white button;
E. A Red Light, below the Blue Light, will power-on indicating the
Software Upgrade has begun;
F. When the module omits an audible chirp and the Red Light
below the Blue Light turns off, the Monitor Panel brain box (black
box) has updated with the required software.