![Rockwell RCV56HCF Скачать руководство пользователя страница 29](http://html1.mh-extra.com/html/rockwell/rcv56hcf/rcv56hcf_designers-manual_1474980029.webp)
RCV56HCF PCI/CardBus Modem Designer’s Guide
1129
ROCKWELL PROPRIETARY INFORMATION
3-7
Table 3-2. Bus Interface Pin Signal Definitions
Label
I/O Type
Signal Name/Description
SYSTEM
XIN,
XOUT
It
Ot2
Crystal In and Crystal Out. Connect XIN and XOUT to a 28.224 MHz external crystal circuit.
VDD
PWR
Digital Supply Voltage. Connect to 3.3V.
GND
GND
Digital Ground. Connect to digital ground.
CARDBUS#
It
CardBus Interface Select. Selects CardBus (low) or PCI Bus (high) drive strength. For PCI Bus, connect to
VCC through 1K ohm.
VGG1
PWR
I/O Voltage Tolerance Reference. Connect to VCC.
VIO
PWR
I/O Signaling Voltage Source. Connect to 3.3V.
PCI BUS INTERFACE
PCICLK
Ip
(in)
PCI Bus Clock. The PCICLK (PCI Bus CLK signal) input provides timing for all transactions on PCI.
CLKRUN#
Ip,
(in, o/d,
s/t/s)
Clock Running. CLKRUN# is an input used to determine the status of CLK and an open drain output used
to request starting or speeding up CLK. Connect to GND through 1K
Ω
for PCI designs.
PCIRST#
Ip
(in)
PCI Bus Reset. PCIRST# (PCI Bus RST# signal) is used to bring PCI-specific registers, sequencers, and
signals to a consistent state.
AD[31:0]
I/Opts
(t/s)
Multiplexed Address and Data. Address and Data are multiplexed on the same PCI pins.
CBE[3:0]#
I/Opts
(t/s)
Bus Command and Bus Enable. Bus Command and Byte Enables are multiplexed on the same PCI pins.
During the address phase of a transaction, C/BE[3:0]# define the bus command. During the data phase,
C/BE[3:0]# are used as Byte Enables.
PAR
I/Opts
(t/s)
Parity. Parity is even parity across AD[31::00] and C/BE[3::0]#. The master drives PAR for address and
write data phases; the Bus Interface drives PAR for read data phases.
FRAME#
I/Opsts
(s/t/s)
Cycle Frame. FRAME# is driven by the current master to indicate the beginning and duration of an access.
IRDY#
I/Opsts
(s/t/s)
Initiator Ready. IRDY# is used to indicate the initiating agent’s (bus master’s) ability to complete the current
data phase of the transaction. IRDY# is used in conjunction with TRDY#.
TRDY#
I/Opsts
(s/t/s)
Target Ready. TRDY# is used to indicate s the Bus Interface’s ability to complete the current data phase of
the transaction. TRDY# is used in conjunction with IRDY#.
STOP#
I/Opsts
(s/t/s)
Stop. STOP# is asserted to indicate the Bus Interface is requesting the master to stop the current
transaction.
IDSEL
Ip
(in)
Initialization Device. IDSEL input is used as a chip select during configuration read and write transactions.
DEVSEL#
I/Opsts
(s/t/s)
Device Select. When actively driven, DEVSEL# indicates the driving device has decoded its address as the
target of the current access. As an input, DEVSEL# indicates whether any device on the bus has been
selected.
TRDY#
I/Opts
(t/s)
Request. TRDY# is used to indicate to the arbiter that this agent desires use of the bus.
GNT#
I/Opts
(t/s)
Grant. GNT# is used to indicate to the agent that access to the bus has been granted.
Содержание RCV56HCF
Страница 69: ...NOTES Inside Back Cover...