Command Reference Manual
1199
3-5
3.2.1.6 I - Identification
This command causes the modem to reports the requested result according to the command parameter.
Syntax
I<value>
Defined Values
<value>
Decimal number corresponding to the selected information.
0
Reports product code, e.g., 56000
1
Reports the least significant byte of the stored checksum in decimal (see firmware
release notes). Reports 255 if the prestored checksum value is FFh.
2
Reports "OK".
3
Reports identification codes in the form VX.X-F_A where:
VX.X =
Firmware version (e.g., V3.00)
F =
Firmware model and ROM Size:
V90 or V34 = V90 or V34 in 1M ROM
V90_2M or V34_2M = V90 or V34 in 2M ROM
A = Application
DLS = Desktop serial
DLP = Desktop parallel
DLL = Low Power PC Card
DL3 = Low Power 3V
DLG = Low Power World Class
Example: V3.000-V90_2M_DLS
Note:
If RPI+ is enabled (see +Hn command), “ROCKWELL RPI (TM)” is
appended.
4
Reports OEM defined identifier string in either Hayes-compatible binary format
(default) or ASCII format (selectable by ConfigurACE), e.g.:
a007840284C6002F
bC60000000
r1005111151012000
r3000111170000000
5
Reports Country Code parameter (see +GCI command), e.g., B5.
6
Reports modem data pump model and internal code revision, e.g.,
RCV56DPF-PLL L8571A Rev 29.00/29.00
7
Reports OK.
Result Codes
OK
<value> = 0 - 7.
ERROR
Otherwise.