Programming and Parameters
3-59
Applications File
(File K)
F
ile
K
Gr
oup
No.
Parameter Name & Description
See
for symbol descriptions
Values
Relate
d
APPLICA
T
IONS (F
ile K)
F
ibe
r Func
ti
ons
620
[Fiber Control]
Controls the Sync and Traverse functions.
621
[Fiber Status]
Status of Sync and Traverse functions.
Read Only
622
[Sync Time]
The time to ramp from the “held speed
reference” to the current speed
reference, after the Sync input is
de-energized.
Default:
Min/Max:
Units:
0.0 Secs
0.0/3600.0 Secs
0.1 Secs
623
[Traverse Inc]
Sets the time period of increasing
frequency.
Default:
Min/Max:
Units:
0.00 Secs
0.00/30.00 Secs
0.01 Secs
624
[Traverse Dec]
Sets the time period of decreasing
frequency.
Default:
Min/Max:
Units:
0.00 Secs
0.00/30.00 Secs
0.01 Secs
625
[Max Traverse]
Sets the amplitude of the triangle wave
speed modulation.
Default:
Min/Max:
Units:
0.00 Hz
0.00/Maximum Speed
0.01 Hz
626
[P Jump]
Sets the amplitude of the square wave
speed modulation.
Default:
Min/Max:
Units:
0.00 Hz
0.00/Maximum Speed
0.01 Hz
E C v3
0
x
x
0
x
x
x
x
x
x
x
x
x
x
x
x
10
0
1
2
3
4
5
6
7
8
9
11
12
13
14
15
1
= Enabled
0
= Disabled
x = Reserved
Bit #
Factory Default Bit Values
Sync Enab
le
Tr
av
erse Ena
Nibble 1
Nibble 2
Nibble 3
Nibble 4
E C v3
0
0
0
0
x
x
x
x
x
x
x
x
x
x
x
x
10
0
1
2
3
4
5
6
7
8
9
11
12
13
14
15
1
= Condition True
0
= Condition False
x = Reserved
Bit #
Factory Default Bit Values
Sync Hold
Sync Ramp
Tr
av
erse On
Tr
av
erse Dec
Nibble 1
Nibble 2
Nibble 3
Nibble 4
E C v3
E C v3
E C v3
E C v3
E C v3
Содержание PowerFlex 70
Страница 4: ...soc 2 Notes ...
Страница 134: ...A 18 Supplemental Drive Information Notes ...
Страница 168: ...Index 14 ...
Страница 169: ......