36
Rockwell Automation Publication 1783-UM007F-EN-P - September 2016
Chapter 2
Get Started
4. Connect a Category 5 Ethernet cable from the flashing switch port to
the Ethernet port on a computer.
or
For 1783-BMS4S2SGL or 1783-BMS4S2SGA switches, do one of the
following:
• Insert a copper SFP module into the Gi1/1 port on the switch. Then
connect a Category 5 Ethernet cable from the SFP module to the
Ethernet port on the computer.
• Connect the Gi1/1 port on the switch to the Ethernet port on the
computer by using a fiber-to-Ethernet media converter.
Once you connect the switch to the computer, the following occurs:
• The status indicator for the port connected to the computer changes
from flashing green to solid green.
• The switch acts as a DHCP server on VLAN 1000 with an address of
169.254.0.1.
• The switch assigns the computer an IP address of 169.254.0.2 on
VLAN 1000.
• The Setup status indicator changes from flashing green to solid
green.
Configure Network Settings via Device Manager on page 39
.
Run Multi-mode Express Setup in Medium Press Mode
Be aware of the following conditions that cause the switch to exit Medium
Press mode.
IMPORTANT
Port Gi1/1 does not flash during setup, but must be used to connect
1783-BMS4S2SGL or 1783-BMS4S2SGA switches to a computer.
IMPORTANT
The IP address of the switch for multi-mode Express Setup is
different than the IP address for single-mode Express Setup.
Condition
Status Indicator Behavior
A non-default configuration exists on the switch.
The Setup status indicator turns red for 10 seconds.
No DHCP response is received for 10 minutes from when
the switch broadcast the request.
IMPORTANT
Before you begin, make sure that your system has a DHCP server configured
to assign the switch an IP address. You can configure a switch to be a DHCP
server, as described on
.
Содержание ArmorStratix 5700 series
Страница 12: ...12 Rockwell Automation Publication 1783 UM007F EN P September 2016 Table of Contents Notes...
Страница 14: ...14 Rockwell Automation Publication 1783 UM007F EN P September 2016 Preface Notes...
Страница 16: ...16 Rockwell Automation Publication 1783 UM007F EN P September 2016 Summary of Changes Notes...
Страница 156: ...156 Rockwell Automation Publication 1783 UM007F EN P September 2016 Chapter 5 Install Stratix 5700 Switches Notes...
Страница 370: ...370 Rockwell Automation Publication 1783 UM007F EN P September 2016 Chapter 7 Configure Switch Features...
Страница 407: ...Rockwell Automation Publication 1783 UM007F EN P September 2016 407 Monitor the Switch Chapter 8...
Страница 409: ...Rockwell Automation Publication 1783 UM007F EN P September 2016 409 Monitor the Switch Chapter 8...
Страница 486: ...486 Rockwell Automation Publication 1783 UM007F EN P September 2016 Appendix A DataTypes Notes...
Страница 494: ...494 Rockwell Automation Publication 1783 UM007F EN P September 2016 Appendix B Port Assignments for CIP Data Notes...
Страница 540: ...540 Rockwell Automation Publication 1783 UM007F EN P September 2016 Appendix D Cables and Connectors Notes...
Страница 547: ......