Rockwell Automation Publication 1783-UM007F-EN-P - September 2016
351
Configure Switch Features
Chapter 7
Custom Smartport Roles
You can create and modify as many as 10 custom Smartport roles for a variety
of custom applications. By default, the switch ports are set to the None port
role. This feature is not available on Stratix 8000/8300 switches.
Avoid Smartport Mismatches
A Smartport mismatch occurs when an attached device does not match the
Smartport role that is applied to the switch port. Mismatches can have adverse
effects on devices and your network.
Mismatches can result in the following conditions:
• Affect the behavior of the attached device
• Lower network performance (reduce the level of quality of service
[QoS]) on CIP, voice, wireless, switch, and router traffic
• Reduce restrictions on guest access to the network
• Reduce protection from denial of service (DoS) attacks on the network
• Disable or shut down the port
We recommend that you always verify which Smartport role is applied to a
port before attaching a device to the port or reconnecting devices.
Port Mirroring
Apply this role to ports monitored by a network analyzer. For more information about port mirroring, see
None
Apply this role to ports if you do not want a specialized Smartport role on the port. This role can be used on connections to any device, including
devices with other Smartport roles.
CS1…CS10
Custom Smartport roles. You can create a customized port role with a user-defined name. See
Table 93 - Smartport Roles (Continued)
Port Role
Description
Содержание ArmorStratix 5700 series
Страница 12: ...12 Rockwell Automation Publication 1783 UM007F EN P September 2016 Table of Contents Notes...
Страница 14: ...14 Rockwell Automation Publication 1783 UM007F EN P September 2016 Preface Notes...
Страница 16: ...16 Rockwell Automation Publication 1783 UM007F EN P September 2016 Summary of Changes Notes...
Страница 156: ...156 Rockwell Automation Publication 1783 UM007F EN P September 2016 Chapter 5 Install Stratix 5700 Switches Notes...
Страница 370: ...370 Rockwell Automation Publication 1783 UM007F EN P September 2016 Chapter 7 Configure Switch Features...
Страница 407: ...Rockwell Automation Publication 1783 UM007F EN P September 2016 407 Monitor the Switch Chapter 8...
Страница 409: ...Rockwell Automation Publication 1783 UM007F EN P September 2016 409 Monitor the Switch Chapter 8...
Страница 486: ...486 Rockwell Automation Publication 1783 UM007F EN P September 2016 Appendix A DataTypes Notes...
Страница 494: ...494 Rockwell Automation Publication 1783 UM007F EN P September 2016 Appendix B Port Assignments for CIP Data Notes...
Страница 540: ...540 Rockwell Automation Publication 1783 UM007F EN P September 2016 Appendix D Cables and Connectors Notes...
Страница 547: ......