Rockwell Automation Publication 1783-UM007F-EN-P - September 2016
329
Configure Switch Features
Chapter 7
Configure REP via Device Manager
From the Configure menu, choose REP.
To create a REP segment, set a segment ID and port type for a switch port.
Table 86 - REP Fields
Field
Description
REP Admin VLAN
The administrative VLAN. The range is 2…4094. The default is VLAN 1.
REP ports are assigned to the same REP Admin VLAN. If the REP Admin VLAN changes, all REP ports are automatically assigned to the new
REP Admin VLAN.
Port Name
The number of the switch port, including port type (such as Fa for Fast Ethernet and Gi for Gigabit Ethernet).
Mode
The administrative mode. To set this mode, from the Configure menu, choose Port Settings.
Segment ID
The ID of the segment. The segment ID range is from 1…1024. If no segment ID is set, REP is disabled.
Port Type
Each REP segment must have exactly two primary edge ports and can have secondary ports to use when a primary port fails. You can specify
preferred primary and secondary ports. Configuring a port as preferred does not mean that it becomes the alternate port but gives it a slight
edge among equal contenders. You can indicate that a port connects to switches that do not support REP.
Choose one of these port types:
• Edge—A secondary edge port that participates in VLAN load balancing.
• Edge no-neighbor—A secondary edge port that is connected to a non-REP switch.
• Edge no-neighbor preferred—A secondary edge port that is connected to a non-REP switch and is the preferred alternate port for VLAN
load balancing.
• Edge no-neighbor primary—A secondary edge port that always participates in VLAN load balancing in this REP segment and is
connected to a non-REP switch.
• Edge no-neighbor primary preferred—An edge port that always participates in VLAN load balancing in this REP segment, is connected
to a non-REP switch, and is the preferred port for VLAN load balancing.
• Edge preferred—A secondary edge port that is the preferred alternate port for VLAN load balancing.
• Edge primary—An edge port that always participates in VLAN load balancing in this REP segment.
• Edge primary preferred—An edge port that always participates in VLAN load balancing in this REP segment and is the preferred port for
VLAN load balancing.
• None—This port is not part of the REP segment. The default is None.
• Preferred—A secondary edge port that is the preferred alternate port for VLAN load balancing.
Содержание ArmorStratix 5700 series
Страница 12: ...12 Rockwell Automation Publication 1783 UM007F EN P September 2016 Table of Contents Notes...
Страница 14: ...14 Rockwell Automation Publication 1783 UM007F EN P September 2016 Preface Notes...
Страница 16: ...16 Rockwell Automation Publication 1783 UM007F EN P September 2016 Summary of Changes Notes...
Страница 156: ...156 Rockwell Automation Publication 1783 UM007F EN P September 2016 Chapter 5 Install Stratix 5700 Switches Notes...
Страница 370: ...370 Rockwell Automation Publication 1783 UM007F EN P September 2016 Chapter 7 Configure Switch Features...
Страница 407: ...Rockwell Automation Publication 1783 UM007F EN P September 2016 407 Monitor the Switch Chapter 8...
Страница 409: ...Rockwell Automation Publication 1783 UM007F EN P September 2016 409 Monitor the Switch Chapter 8...
Страница 486: ...486 Rockwell Automation Publication 1783 UM007F EN P September 2016 Appendix A DataTypes Notes...
Страница 494: ...494 Rockwell Automation Publication 1783 UM007F EN P September 2016 Appendix B Port Assignments for CIP Data Notes...
Страница 540: ...540 Rockwell Automation Publication 1783 UM007F EN P September 2016 Appendix D Cables and Connectors Notes...
Страница 547: ......