b. If the load is connected for NPN configuration but to a 

power supply other than that to the sensor or via a load 
enabling contact (e.g. a relay contact in series with the load), 
select dedicated NPN.

Selection can be made as follows:
1.

To access output type:

 Press and hold the push button for 12 

seconds (until both LEDs start flashing synchronously). Upon 
button release, the current setting of output type is indicated 
by the slow flashing of the LED(s) as follows:
• Auto PNP/NPN: both LEDs flashing
• Dedicated NPN: green LED flashing
• Dedicated PNP: yellow LED flashing

2.

To change output type:

 Press and release the push button 

within 10 seconds to select desired type. Each button 
activation cycles to the next output setting. The type selected 
is indicated by the LEDs. The sensor retains the setting per the 
last button depression and returns to the RUN mode 10 
seconds after the last button is pressed.

Push Button Lock/Unlock

The push button or remote teach (RT) can be used to prevent 
unauthorized users from changing teach settings.

To lock the push button:

 press and release the button three 

times within three seconds. Both LEDs flash synchronously for 
three seconds indicating that the push button is now locked.

To unlock the push button: 

press and release the button three 

times within three seconds. Both LEDs flash asynchronously for 
three seconds indicating that the push button is now unlocked.

Permanent Lock: 

The push button may be permanently locked 

by connecting the white wire (pin 2) to –V.

Remote Teach (RT)

The sensor can be taught remotely via the white wire (pin 2). 
Connection to +V acts the same as the button being pressed and 
no connection is the same as the button not being pressed. The 
sensor can be taught by following the same teach/timing 
sequence as used in the push button teach (e.g., connect to the 
+V for more than three seconds to teach the “target,” disconnect 
from the +V; remove the target and connect to the +V for less 
than one second to teach the “no target” condition. All push 
button functions can also be carried out via RT.

IO-Link

See instructions for IO-Link on 

www.ab.com

. Remote Teach (pin 2) 

is disabled in IO-Link operation. If output is selected as dedicated 
NPN, IO-Link communication is unavailable.

Wiring Diagrams

The quick-disconnect connector is shown below. The pin 
numbers correspond to male connectors on the sensor.

Micro (M12) Male QD Pigtail/Integral Pico (M8) Male QD 

4

3

1

2

3

2

1

4

M12 Male

M8 Male

Output Wiring

Normal operation: no connection. (Disabled in IO-Link operation.) 

Remote Teach: refer to the Remote Teach section.

Push Button Lock: connect to -V. Refer to the Push Button Lock/Unlock section.

Approximate Dimensions [mm (in.)]

Accessories: Stainless Steel Mounting Brackets

1) 60-BJS-L1

2) 60-BJT-L2

3) 60-2619 VisiSight-compatible swivel/tilt mounting bracket

Output: Auto PNP/NPN or IO-Link

Remote Teach/Lock 

+V

-V

Brown (1)
White (2)
Black (4)
Blue (3)

12

(0.47)

M8 x 1

34

(1.34)

22.9

(0.90)

25.4
(1.0)

2.6

(0.10)

20

(0.79)

12

(0.47)

34

(1.34)

22.9

(0.90)

25.4
(1.0)

2.6

(0.10)

20

(0.79)

2.8

(0.11)

Clearance for

M3 or #4-40 screw

(2 places)

Clearance for

M3 or #4-40 screw

(2 places)

12

(0.47)

18.6

(0.73) 33

(1.3)

14

(0.55)

24

(0.95)

8 (0.32)

15 °

R 25.4

(R 1.0)

30°

20°

63.5

(2.5)

8

(0.32)

14

(0.55)

R 25.4

(1.0)

12

(0.47)

18.6

(0.73)

33

(1.3)

10°

Отзывы: