B-2
Adapter Parameters
PowerFlex® 755 Drive Embedded EtherNet/IP Adapter User Manual
Publication 750COM-UM001A-EN-P
Parameter List
Parameter
No. Name and Description
Details
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
[DL From Net 01]
[DL From Net 02]
[DL From Net 03]
[DL From Net 04]
[DL From Net 05]
[DL From Net 06]
[DL From Net 07]
[DL From Net 08]
[DL From Net 09]
[DL From Net 10]
[DL From Net 11]
[DL From Net 12]
[DL From Net 13]
[DL From Net 14]
[DL From Net 15]
[DL From Net 16]
Sets the port number and parameter number
to which the selected Datalinks should
connect. Each selected port/parameter will be
written with data received from the network.
These are parameters written by the controller
(outputs from the controller).
If setting the value manually, the parameter
value = (10000 * port number) + (destination
parameter number). For example, suppose
you want to use Parameter 01 - [DL From Net
01] to write to Parameter 01 of an optional
encoder card plugged into drive Port 5. The
value for Parameter 01 - [DL From Net 01]
would be 50001 [(10000 * 5) + 1].
Default:
0
Default:
0
Default:
0
Default:
0
Default:
0
Default:
0
Default:
0
Default:
0
Default:
0
Default:
0
Default:
0
Default:
0
Default:
0
Default:
0
Default:
0
Default:
0
Minimum:
0
Maximum:
159999
Type:
Read/Write
Reset Required: No
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
[DL To Net 01]
[DL To Net 02]
[DL To Net 03]
[DL To Net 04]
[DL To Net 05]
[DL To Net 06]
[DL To Net 07]
[DL To Net 08]
[DL To Net 09]
[DL To Net 10]
[DL To Net 11]
[DL To Net 12]
[DL To Net 13]
[DL To Net 14]
[DL To Net 15]
[DL To Net 16]
Sets the port number and parameter number
to which the selected Datalinks should
connect. Each selected port/parameter will be
read and their values transmitted over the
network to the controller. These are
parameters read by the controller (inputs to
the controller).
If setting the value manually, the parameter
value = (10000 * port number) + (origination
parameter number). For example, suppose
you want to use Parameter 17 - [DL To Net
01] to read Parameter 01 of an optional I/O
card plugged into drive Port 4. The value for
Parameter 17 - [DL To Net 01] would be
40001 [(10000 * 4) + 1].
Default:
0
Default:
0
Default:
0
Default:
0
Default:
0
Default:
0
Default:
0
Default:
0
Default:
0
Default:
0
Default:
0
Default:
0
Default:
0
Default:
0
Default:
0
Default:
0
Minimum:
0
Maximum:
159999
Type:
Read/Write
Reset Required: No
Содержание PowerFlex 755 Drive
Страница 1: ...USER MANUAL Firmware Version 1 xxx PowerFlex 755 Drive Embedded EtherNet IP Adapter...
Страница 152: ...7 6 Troubleshooting PowerFlex 755 Drive Embedded EtherNet IP Adapter User Manual Publication 750COM UM001A EN P Notes...
Страница 166: ...A 2 Specifications PowerFlex 755 Drive Embedded EtherNet IP Adapter User Manual Publication 750COM UM001A EN P Notes...
Страница 224: ...G 8 Glossary PowerFlex 755 Drive Embedded EtherNet IP Adapter User Manual Publication 750COM UM001A EN P Notes...
Страница 229: ...Index 5 PowerFlex 755 Drive Embedded EtherNet IP Adapter User Manual Publication 750COM UM001A EN P Notes...
Страница 230: ...Index 6 PowerFlex 755 Drive Embedded EtherNet IP Adapter User Manual Publication 750COM UM001A EN P Notes...
Страница 231: ......