![Rockwell Automation PowerFlex 750-Series Скачать руководство пользователя страница 37](http://html.mh-extra.com/html/rockwell-automation/powerflex-750-series/powerflex-750-series_user-manual_1475453037.webp)
PowerFlex 750-Series Drive DeviceNet Option Module User Manual
Publication 750COM-UM002A-EN-P
Chapter
4
Configuring the I/O
This chapter provides instructions on how to configure a Rockwell
Automation ControlLogix controller to communicate with the Option
Module and connected PowerFlex drive.
Important: Since the Option Module and PowerFlex 750-Series drive
are 32-bit devices, the ControlLogix controller (also a
32-bit platform) is used for example purposes in this
chapter and throughout this manual. We recommend using
only a 32-bit platform Logix controller with this Option
Module and PowerFlex 750-Series drive to simplify
configuration and ladder logic programs, and maximize
drive performance. If you must use a 16-bit controller
(PLC-5, SLC 500, etc.), we recommend using a
20-COMM-D adapter that is mounted onto a
20-750-20COMM Option Card installed in drive Port 6. In
this case, refer to the Rockwell Automation Technical
Support Knowledgebase web site at
www.rockwellautomation.com/knowledgebase
for details
on configuring and using the I/O, and explicit messaging.
Using RSLinx Classic
RSLinx Classic, in all its variations (Lite, Gateway, OEM, etc.), is used
to provide a communication link between the computer, network, and
controller. RSLinx Classic requires its network-specific driver to be
configured before communications are established with network
devices. To configure the RSLinx driver:
1. Start RSLinx and select Communications > Configure Drivers to
display the Configure Drivers screen.
2. In the Available Driver Types box, select “DeviceNet Drivers” and
then click Add New to display the DeviceNet Driver Selection
screen.
3. In the Available DeviceNet Drivers list, select the PC connection
adapter (1784-PCD, 1784-PCID, 1784-PCIDS or 1770-KFD)
connected to your computer and then click Select to display the
Driver Configuration screen.
4. Configure the driver for your computer and network settings and
click OK. The Configure Drivers screen reports the progress of the
configuration.
Topic
Page
Содержание PowerFlex 750-Series
Страница 136: ...G 8 Glossary PowerFlex 750 Series Drive DeviceNet Option Module User Manual Publication 750COM UM002A EN P Notes ...
Страница 141: ...Index 5 PowerFlex 750 Series Drive DeviceNet Option Module User Manual Publication 750COM UM002A EN P Notes ...
Страница 142: ...Index 6 PowerFlex 750 Series Drive DeviceNet Option Module User Manual Publication 750COM UM002A EN P Notes ...
Страница 143: ......