3-116
Programming and Parameters
PowerFlex 700S Phase II AC Drive User Manual -
Publication 20D-UM006G-EN-P – July 2008
1161
EGR Config
Configuration for the Electrical Gear Ratio (EGR) user function. Setting bit 7 “EGR” of
[UserFunct Enable] enables the EGR user function. The
combination of bit 0 “Output Sel 0” and bit 1 “Output Sel 1” determines the output of the EGR user function as follows:
Note: This parameter was added for firmware version 4.001.
1162
EGR Mul
Multiplier (numerator) of the EGR user function position input.
(
[EGR Pos Input] x Par 1162 [EGR Mul]) /
[EGR Pos
Output]
Note: This parameter was added for firmware version 4.001.
Default:
Min/Max:
1.0
-/+2000000.0
✓
RW 32-bit
Integer
1163
EGR Div
Divisor (denominator) of the EGR user function position input.
(
[EGR Pos Input] x
[EGR Mul]) / Par 1163 [EGR Div] =
[EGR Pos
Output]
Note: This parameter was added for firmware version 4.001.
Default:
Min/Max:
1.0
+1.0/+2000000.0
✓
RW 32-bit
Integer
1164
EGR Pos Input
Position reference input to the Electrical Gear Ratio user function. This parameter can be
linked to a position reference source, such as
[VirtEncPositFast].
Note: This parameter was added for firmware version 4.001.
Default:
Min/Max:
0.0
-/+2147483648.0
✓
RW 32-bit
Integer
1165
EGR Pos Output
Position reference output from the Electrical Gear Ratio user function. This parameter can be
linked to a position reference sink, such as
[Heidn VM Pos Ref].
Note: This parameter was added for firmware version 4.001.
Default:
Min/Max:
0.0
-/+2147483648.0
RO 32-bit
Integer
1166
EGR Pos Preset
A preset value for the Electrical Gear Ratio user function. This value is set to the value in
[EGR Pos Output] when bits 0 “Output Sel 0” and 1 “Output Sel 1” of
Config] are set.
Note: This parameter was added for firmware version 4.001.
Default:
Min/Max:
0.0
-/+2147483648.0
✓
RW 32-bit
Integer
1170
MC Generic 1
For Future Use.
Note: This parameter was added for firmware version 4.001.
Default:
Min/Max:
0
+/-32767
RW 16-bit
Integer
1171
MC Generic 2
For Future Use.
Note: This parameter was added for firmware version 4.001.
Default:
Min/Max:
0
+/-32767
RW 16-bit
Integer
1172
MC Generic 3
For Future Use.
Note: This parameter was added for firmware version 4.001.
Default:
Min/Max:
0
+/-32767
RW 16-bit
Integer
1173
MC Generic 4
For Future Use.
Note: This parameter was added for firmware version 4.001.
Default:
Min/Max:
0
+/-32767
RW 16-bit
Integer
1174
MC Generic 5
For Future Use.
Note: This parameter was added for firmware version 4.001.
Default:
Min/Max:
0
+/-32767
RW 16-bit
Integer
1175
MC Generic 6
For Future Use.
Note: This parameter was added for firmware version 4.001.
Default:
Min/Max:
0
+/-32767
RW 16-bit
Integer
1176
MC Generic 7
For Future Use.
Note: This parameter was added for firmware version 4.001.
Default:
Min/Max:
0
+/-32767
RW 16-bit
Integer
1177
MC Generic 8
For Future Use.
Note: This parameter was added for firmware version 4.001.
Default:
Min/Max:
0
+/-32767
RW 16-bit
Integer
No.
Name
Description
Values
Linkab
le
R
ead-Wr
ite
Da
ta
T
ype
Bit 1 Bit 0 Description
0
0
[EGR Pos Output] is set to zero
0
1
Par 1165 [EGR Pos Output] is active
1
0
Par 1165 [EGR Pos Output] is set to the value of
[EGR Pos Input]
1
1
Par 1165 [EGR Pos Output] is set to the value of
[EGR Pos preset]
Options
Res
er
ve
d
Res
er
ve
d
Res
er
ve
d
Res
er
ve
d
Res
er
ve
d
Res
er
ve
d
Res
er
ve
d
Res
er
ve
d
Res
er
ve
d
Res
er
ve
d
Res
er
ve
d
Res
er
ve
d
Res
er
ve
d
Res
er
ve
d
Out
put
Sel
1
Out
put
Sel
0
Default
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Bit
15 14 13 12 11 10 9
8
7
6
5
4
3
2
1
0
0 = False
1 = True
Содержание PowerFlex 700S
Страница 1: ...USER MANUAL Firmware Versions 1 xxx 4 002 PowerFlex 700S High Performance AC Drive Phase II Control ...
Страница 58: ...2 8 Start Up PowerFlex 700S Phase II AC Drive User Manual Publication 20D UM006G EN P July 2008 Notes ...
Страница 147: ...Programming and Parameters 3 89 PowerFlex 700S Phase II AC Drive User Manual Publication 20D UM006G EN P July 2008 ...
Страница 278: ...D 8 HIM Overview PowerFlex 700S Phase II AC Drive User Manual Publication 20D UM006G EN P July 2008 Notes ...
Страница 316: ...Index 6 PowerFlex 700S Phase II AC Drive User Manual Publication 20D UM006G EN P July 2008 ...
Страница 317: ......