3-82
Programming and Parameters
PowerFlex 700S Phase II AC Drive User Manual -
Publication 20D-UM006G-EN-P – July 2008
No.
Name
Description
Values
Linka
b
le
Read-Write
Data T
ype
650
DPI In DataType
Sets the data type for each word communicated from an external controller to the PowerFlex 700S drive via a DPI communication module. Setting a bit High will
configure the associated word as a Real data type and setting the bit Low will configure it for Integer data type.
651
652
653
654
655
656
657
658
DPI Data In A1
DPI Data In A2
DPI Data In B1
DPI Data In B2
DPI Data In C1
DPI Data In C2
DPI Data In D1
DPI Data In D2
These parameters display the input values communicated from DPI communication modules
to the PowerFlex 700S drive.
Default:
Min/Max:
0
-/+32 (dependant on
[DPI In
DataType])
RO 32-bit
Integer
659
DPI Out DataType
Sets the data type for each word communicated from the PowerFlex 700S drive to an external controller via a DPI communication module. Setting a bit High will
configure the associated word as a Real data type and setting the bit Low will configure it for Integer data type.
660
661
662
663
664
665
666
667
DPI Data Out A1
DPI Data Out A2
DPI Data Out B1
DPI Data Out B2
DPI Data Out C1
DPI Data Out C2
DPI Data Out D1
DPI Data Out D2
These parameters display the output values communicated from the PowerFlex 700S drive to
DPI communication modules.
Default:
Min/Max:
0
-/+32 (dependant on
[DPI Out
DataType])
✓
RW Set by
Par 659
669
Write Mask
Enables/disables write access (parameters, links, etc.) for DPI ports. Changes to this parameter only become effective when power is cycled, the drive is reset or
bit 15 “Security” of
[Write Mask Act], transitions from “1” to “0.”
Note: This parameter was added for firmware version 3.01.
Options
DPI D2
Re
al
DPI D1
Re
al
DPI C2
Re
al
DPI C1
Re
al
DPI B2
Re
al
DPI B1
Re
al
DPI A2
Re
al
DPI A1
Re
al
Default
0
0
0
0
0
0
0
0
Bit
7
6
5
4
3
2
1
0
0 = False
1 = True
Options
D
P
I D2 Real
D
P
I D1 Real
D
P
I C2 Real
D
P
I C1 Real
D
P
I B2 Real
D
P
I B1 Real
D
P
I A2 Real
D
P
I A1 Real
Default
0
0
0
0
0
0
0
0
Bit
7
6
5
4
3
2
1
0
0 = False
1 = True
Options
Dr
iv
eLog
ix
Rese
rv
ed
In
t DPI
Co
mm
Rese
rv
ed
A
ux
DP
I Conn
Ext D
P
I Conn
Loc
al HI
M
Te
rm
inal Blk
Default
0
0
0
0
0
0
0
0
Bit
7
6
5
4
3
2
1
0
0 = False
1 = True
Содержание PowerFlex 700S
Страница 1: ...USER MANUAL Firmware Versions 1 xxx 4 002 PowerFlex 700S High Performance AC Drive Phase II Control ...
Страница 58: ...2 8 Start Up PowerFlex 700S Phase II AC Drive User Manual Publication 20D UM006G EN P July 2008 Notes ...
Страница 147: ...Programming and Parameters 3 89 PowerFlex 700S Phase II AC Drive User Manual Publication 20D UM006G EN P July 2008 ...
Страница 278: ...D 8 HIM Overview PowerFlex 700S Phase II AC Drive User Manual Publication 20D UM006G EN P July 2008 Notes ...
Страница 316: ...Index 6 PowerFlex 700S Phase II AC Drive User Manual Publication 20D UM006G EN P July 2008 ...
Страница 317: ......