Rockwell Automation Publication 440R-UM009C-EN-P - July 2019
Chapter 6
AOP Controller Tags
Dual GuardLink (DG) Tags
DG safety relays have GuardLink input capability. The AOP includes tags that
are related to the DG relay (see
) and tags related to the GuardLink
circuits (see
Table 3 - DG Relay Tags (Tag name prefix: ENETRname:I.Relayx_GSR_DG.)
Name
Data Type
Definition
SafetyInput01
BOOL
Safety Input 1 Status - Indicates whether safety input circuit 1 is ON or OFF.
0 = The input channel is OFF.
1 = The input channel is ON.
SafetyInput02
BOOL
Safety Input 2 Status - Indicates whether safety input circuit 2 is ON or OFF.
0 = The input channel is OFF.
1 = The input channel is ON.
PtS12
BOOL
S12 Status - Indicates whether terminal S12 of circuit IN01 is ON or OFF.
0 = The terminal is OFF.
1 = The terminal is ON.
PtS22
BOOL
S22 Status - Indicates whether terminal S22 of circuit IN02 is ON or OFF.
0 = The terminal is OFF.
1 = The terminal is ON.
PtS32
BOOL
S32 Status - Indicates whether terminal S32 of circuit IN02 is ON or OFF.
0 = The terminal is OFF.
1 = The terminal is ON.
PtS42
BOOL
S42 Status - Indicates whether terminal S42 of circuit IN02 is ON or OFF.
0 = The terminal is OFF.
1 = The terminal is ON.
PtS11
BOOL
S11 Status - Indicates whether terminal S11 is ON or OFF.
0 = The terminal is OFF.
1 = The terminal is ON.
PtS21
BOOL
S21 Status - Indicates whether terminal S21 is ON or OFF.
0 = The terminal is OFF.
1 = The terminal is ON.
PtX1
BOOL
X1 Status - Indicates whether terminal X1 is ON or OFF.
0 = The terminal is OFF.
1 = The terminal is ON.
PtX2
BOOL
X2 Status - Indicates whether terminal X2 is ON or OFF.
0 = The terminal is OFF.
1 = The terminal is ON.
PtX3
BOOL
X3 Status - Indicates whether terminal X3 is ON or OFF.
0 = The terminal is OFF.
1 = The terminal is ON.
PtX4
BOOL
X4 Status - Indicates whether terminal X4 is ON or OFF.
0 = The terminal is OFF.
1 = The terminal is ON.
Pt13_14
BOOL
13/14 Status - Indicates whether output relays contacts at terminals 13/14 are closed or open.
0 = The contacts are open.
1 = The contacts are closed.
Pt23_24
BOOL
23/24 Status - Indicates whether output relays contacts at terminals 23/24 are closed or open.
0 = The contacts are open.
1 = The contacts are closed.
ResetRequired1
BOOL
Reset Required Indication – Indicates whether the DG relay shows all monitored input conditions (both IN1 and IN2, as
configured) are ON and the safety relay Output is OFF (0).
0 = No reset required.
1 = Waiting for reset signal at terminal X4.
Содержание Guardmaster 440R-ENETR
Страница 12: ...12 Rockwell Automation Publication 440R UM009C EN P July 2019 Chapter 1 Product Overview Notes...
Страница 62: ...62 Rockwell Automation Publication 440R UM009C EN P July 2019 Chapter 6 AOP ControllerTags Notes...
Страница 76: ...76 Rockwell Automation Publication 440R UM009C EN P July 2019 Chapter 9 Explicit Communication Notes...
Страница 78: ...78 Rockwell Automation Publication 440R UM009C EN P July 2019 Appendix A Specifications Notes...
Страница 80: ...80 Rockwell Automation Publication 440R UM009C EN P July 2019 Appendix B Regulatory Approvals Notes...
Страница 84: ...84 Rockwell Automation Publication 440R UM009C EN P July 2019 Index Notes...
Страница 85: ......