Rockwell Automation Allen-Bradley VisiSight 42JT Series Скачать руководство пользователя страница 3

3

• Auto PNP/NPN: both LEDs flashing
• Dedicated NPN: green LED flashing
• Dedicated PNP: yellow LED flashing

2. To change output type: Press and release the pushbutton 

within ten seconds to select desired type. Each press of the 
button will cycle to the next output setting. The type selected 
is indicated by the LEDs. The sensor retains the setting per the 
last button depression and returns to the RUN mode ten 
seconds after the last button is pressed. 

Pushbutton Lock/Unlock

The pushbutton or remote teach (RT) can be used to prevent 
unauthorized users from changing teach settings.

To lock the pushbutton: press and release the button three 
times within three seconds. Both LEDs flash synchronously for 
three seconds indicating that the pushbutton is now locked.

To unlock the pushbutton: press and release the button three 
times within three seconds. Both LEDs flash asynchronously for 
three seconds indicating that the pushbutton is now unlocked.

Permanent Lock: The pushbutton may be permanently locked 
by connecting the white wire (pin 2) to –V.

Remote Teach (RT)

The sensor can be taught remotely via the white wire (pin 2). 
Connection to +V acts the same as the button being pressed and 
no connection is the same as the button not being pressed. The 
sensor can be taught by following the same teach/timing 
sequence as used in the pushbutton teach. For example, connect 
to the +V for more than three seconds to align and install the 
reflector, disconnect from the +V; while the reflector is in the 
sensor’s field of view and there is no target, connect to the +V for 
less than one second to complete the teach process. All 
pushbutton functions can also be carried out via RT.

Wiring Diagrams

The quick-disconnect connector is shown in the following 
diagrams. The pin numbers correspond to male connectors on 
the sensor.

Micro (M12) Male QD on Pigtail and 
Integral Pico (M8) Male QD 

Output Wiring

Normal operation: no connection. 
Remote Teach: connect to +V. Refer to the Remote Teach section.
Pushbutton lock: connect to -V. Refer to the Pushbutton Lock/Unlock 
section.

Approximate Dimensions [mm (in.)]

4

3

1

2

3

2

1

4

M12 Male

M8 Male

Brown (1)

White (2)

Black (4)

Blue (3)

+V

Remote Teach/Lock 

Output (Auto NPN or PNP)

-V

LO

DO

12

(0.47)

M8 x 1

34

(1.34)

22.9

(0.90)

25.4

(1.0)

2.6

(0.10)

20

(0.79)

12

(0.47)

34

(1.34)

22.9

(0.90)

25.4

(1.0)

2.6

(0.10)

20

(0.79)

2.8

(0.11)

Clearance for

M3 or #4-40 screw

(2 places)

Clearance for

M3 or #4-40 screw

(2 places)

Содержание Allen-Bradley VisiSight 42JT Series

Страница 1: ...y UL 20 50 C 4 122 F Alignment Indication For short range applications the visible light beam of the sensor suffices as alignment aid The alignment feature may be used for longer range applications Alignment of the sensor is indicated via change in intensity of the green LED in the Alignment Mode as follows 1 Press and release the pushbutton twice within three seconds After three seconds the green...

Страница 2: ... of target and no target Teach Light Operate L O or Dark Operate D O The default setting of the output is Dark Operate DO DO setting means that output turns ON when the target is detected If the application requires the output to turn OFF when the target is detected the setting may be changed to Light Operate LO 1 To access the teach output mode setting 2 To change the sensor output mode setting O...

Страница 3: ...the white wire pin 2 Connection to V acts the same as the button being pressed and no connection is the same as the button not being pressed The sensor can be taught by following the same teach timing sequence as used in the pushbutton teach For example connect to the V for more than three seconds to align and install the reflector disconnect from the V while the reflector is in the sensor s field...

Страница 4: ...es Stainless Steel Mounting Brackets 60 BJS L1 0 0 2 0 66 0 4 1 31 0 6 1 97 0 8 2 62 1 0 3 28 0 10 20 30 40 Size mm Distance m ft 12 0 47 18 6 0 73 33 1 3 14 0 55 24 0 95 8 0 32 15 R 25 4 R 1 0 60 BJT L2 Reflectors 92 118 Micro cube reflector 30 20 63 5 2 5 8 0 32 14 0 55 R 25 4 1 0 12 0 47 18 6 0 73 33 1 3 10 40 0 1 58 51 0 2 01 10 0 39 51 0 2 01 38 0 1 50 3 5 0 14 60 7 2 39 7 0 0 28 20 0 79 ...