Installation Instructions
42JT VisiSight™ Photoelectric Clear Object Sensors
IMPORTANT: SAVE THESE INSTRUCTIONS FOR FUTURE USE.
Default Settings:
Output Mode: Dark Operate (Output ON when the light
between sensor and reflector is blocked)
Output Type: Auto PNP or NPN (The sensor monitors the load
connection continuously and automatically configures the
output to PNP or NPN)
Sensor User Interface
LED Status
The table below provides LED status in the RUN mode i.e., during
operation, the sensor is always in RUN mode, except when being
taught.
Mounting the Sensor
Securely mount the sensor on a firm, stable surface or support.
An application which is subject to excessive vibration or shifting
may cause intermittent operation. For installation convenience,
Rockwell Automation offers a wide range of mounting brackets
(see the Accessories section for more details).
Green
OFF
Power is OFF
ON
Power is ON
Flashing (6 Hz)
Unstable light level (0.5 <
margin < 2)
Flashing (1.5 Hz)
Output short circuit protection
active
Yellow
OFF
Output de-energized
ON
Output energized
Yellow LED
Pushbutton
Green LED
General Specifications
Replace with A2 for 2 m cable, F4 for 4-pin DC micro (M12) QD, P4 on
4-pin DC pico (M8) QD.
ECOLAB on P4 and A2 models only
UL: -20…+50°C (-4…122°F)
Alignment Indication
For short range applications the visible light beam of the sensor
suffices as alignment aid.
The alignment feature may be used for longer range applications.
Alignment of the sensor is indicated via change in intensity of the
green LED in the Alignment Mode, as follows:
1. Press and release the pushbutton twice within three seconds.
After three seconds, the green LED turns OFF for 0.5 second
indicating the sensor is in the alignment mode.
2. Align the sensor to the reflector. The intensity of green LED
increases with better alignment. Secure it in a position that
42JT-C2LAT1-
Environmental
Certifications
cULus and CE Marked for all applicable directives
Operating Environment
IP67, IP69K, ECOLAB
Operating Temperature [C (F)]
-20…+60° (-4…+140°)
Storage Temperature [C (F)]
-20…+80° (-4…+179°)
Optical
Light Source
Visible red 660 nm
Sensing Range
0…2 m (0…6.6 ft)
Adjustments
Pushbutton
Electrical
Voltage
10…30V DC
Current Consumption
30 mA max.
Sensor Protection
Reverse polarity, short circuit protection
Outputs
Response Time
0.5 ms
Output Type
Auto NPN or PNP
Output Function
Selectable light operate or dark operate
Output Current
100 mA max.
Output Leakage Current
10 μA max.
Mechanical
Housing Material
ABS
Lens Material
PMMA
Cover Material
PMMA
Connection Types
2 m PUR cable, 4-pin DC micro (M12) QD on a 150 mm
PUR pigtail, 4-pin pico (M8) integral QD
Optional Accessories
Mounting brackets, cordsets