Rockwell Automation Allen-Bradley VisiSight 42JT Series Скачать руководство пользователя страница 1

Installation Instructions

42JT VisiSight™ Photoelectric Clear Object Sensors

IMPORTANT: SAVE THESE INSTRUCTIONS FOR FUTURE USE.

Default Settings:

Output Mode:  Dark Operate (Output ON when the light 
between sensor and reflector is blocked)
Output Type: Auto PNP or NPN (The sensor monitors the load 
connection continuously and automatically configures the 
output to PNP or NPN)

Sensor User Interface

LED Status

The table below provides LED status in the RUN mode i.e., during 
operation, the sensor is always in RUN mode, except when being 
taught.

Mounting the Sensor

Securely mount the sensor on a firm, stable surface or support. 
An application which is subject to excessive vibration or shifting 
may cause intermittent operation. For installation convenience, 
Rockwell Automation offers a wide range of mounting brackets 
(see the Accessories section for more details).

Green

OFF

Power is OFF

ON

Power is ON

Flashing (6 Hz)

Unstable light level (0.5 < 

margin < 2)

Flashing (1.5 Hz)

Output short circuit protection 

active

Yellow

OFF

Output de-energized

ON

Output energized

Yellow LED

Pushbutton

Green LED

General Specifications

Replace with A2 for 2 m cable, F4 for 4-pin DC micro (M12) QD, P4 on 
4-pin DC pico (M8) QD.

ECOLAB on P4 and A2 models only

UL: -20…+50°C (-4…122°F)

Alignment Indication

For short range applications the visible light beam of the sensor 
suffices as alignment aid.

The alignment feature may be used for longer range applications. 
Alignment of the sensor is indicated via change in intensity of the 
green LED in the Alignment Mode, as follows:

1. Press and release the pushbutton twice within three seconds. 

After three seconds, the green LED turns OFF for 0.5 second 
indicating the sensor is in the alignment mode. 

2. Align the sensor to the reflector. The intensity of green LED 

increases with better alignment. Secure it in a position that 

42JT-C2LAT1-

Environmental

Certifications

cULus and CE Marked for all applicable directives

Operating Environment

IP67, IP69K, ECOLAB

Operating Temperature [C (F)]

-20…+60° (-4…+140°)

Storage Temperature [C (F)]

-20…+80° (-4…+179°) 

Optical

Light Source

Visible red 660 nm

Sensing Range

0…2 m (0…6.6 ft)

Adjustments

Pushbutton

Electrical

Voltage

10…30V DC

Current Consumption

30 mA max.

Sensor Protection

Reverse polarity, short circuit protection

Outputs

Response Time

0.5 ms

Output Type

Auto NPN or PNP

Output Function

Selectable light operate or dark operate

Output Current

100 mA max.

Output Leakage Current

10 μA max.

Mechanical

Housing Material

ABS

Lens Material

PMMA

Cover Material

PMMA

Connection Types

2 m PUR cable, 4-pin DC micro (M12) QD on a 150 mm 
PUR pigtail, 4-pin pico (M8) integral QD

Optional Accessories

Mounting brackets, cordsets

Содержание Allen-Bradley VisiSight 42JT Series

Страница 1: ...y UL 20 50 C 4 122 F Alignment Indication For short range applications the visible light beam of the sensor suffices as alignment aid The alignment feature may be used for longer range applications Alignment of the sensor is indicated via change in intensity of the green LED in the Alignment Mode as follows 1 Press and release the pushbutton twice within three seconds After three seconds the green...

Страница 2: ... of target and no target Teach Light Operate L O or Dark Operate D O The default setting of the output is Dark Operate DO DO setting means that output turns ON when the target is detected If the application requires the output to turn OFF when the target is detected the setting may be changed to Light Operate LO 1 To access the teach output mode setting 2 To change the sensor output mode setting O...

Страница 3: ...the white wire pin 2 Connection to V acts the same as the button being pressed and no connection is the same as the button not being pressed The sensor can be taught by following the same teach timing sequence as used in the pushbutton teach For example connect to the V for more than three seconds to align and install the reflector disconnect from the V while the reflector is in the sensor s field...

Страница 4: ...es Stainless Steel Mounting Brackets 60 BJS L1 0 0 2 0 66 0 4 1 31 0 6 1 97 0 8 2 62 1 0 3 28 0 10 20 30 40 Size mm Distance m ft 12 0 47 18 6 0 73 33 1 3 14 0 55 24 0 95 8 0 32 15 R 25 4 R 1 0 60 BJT L2 Reflectors 92 118 Micro cube reflector 30 20 63 5 2 5 8 0 32 14 0 55 R 25 4 1 0 12 0 47 18 6 0 73 33 1 3 10 40 0 1 58 51 0 2 01 10 0 39 51 0 2 01 38 0 1 50 3 5 0 14 60 7 2 39 7 0 0 28 20 0 79 ...