54
Rockwell Automation Publication 20P-TG003B-EN-P - September 2021
Chapter 3
Access Procedures
115V AC to 24V DC I/O
Converter Circuit Board
Removal and Installation
Remove the 115V AC to 24V DC I/O Converter Circuit Board
1.
General Safety Precautions on page 10
2.
Remove power from the drive. See
Remove Power from the Drive on
3.
Remove the covers from the drive. See
Remove the Protective Covers from
.
4.
Remove the plug-in I/O terminal block with the wiring kept in place.
5.
Remove the two screws that secure the I/O converter board to the stand-
offs on the control board and remove the I/O converter board.
6.
Remove the two stand-offs and washers from the control board.
IMPORTANT
Mark all connections and wires before removal to avoid incorrect
wiring during reassembly.
=
Remove two screws
Tightening torque for re-assembly is
1.0 N
•
m (8.9 lb
•
in)
Remove two stand-offs and washers
Tightening torque for re-assembly is
1.0 N
•
m (8.9 lb
•
in)
Содержание Allen-Bradley PowerFlex 4M
Страница 1: ...PowerFlex Digital DC Drive Frame C Bulletin Number 20P Hardware Service Manual Original Instructions ...
Страница 8: ...8 Rockwell Automation Publication 20P TG003B EN P September 2021 Preface Notes ...