Rockwell Automation Publication 2715P-UM001C-EN-P - March 2019
11
Chapter
1
Overview
About the PanelView 5510
Terminals
The PanelView™ 5510 terminals are operator interface devices that monitor and
control devices attached to ControlLogix® L7 or L8 controllers, and
CompactLogix™ L1, L2, or L3 controllers over an EtherNet/IP™ network.
Animated graphic and text displays provide a view into the operating state of a
machine or process. Operators interact with the control system by using the
touch screen or keypad of the terminal.
The PanelView 5510 terminals include these features and capabilities:
• Tightly integrated control and design environment allows information to
be shared between the PanelView 5510 terminal and the Logix platforms.
• The Studio 5000® environment provides one point of access for both View
Designer and Logix Designer applications
(1)
.
• Connection up to four ControlLogix L7 or L8 controllers, or
CompactLogix L1, L2, or L3 controllers.
(2)
• Supports a maximum of 100 user-defined screens.
• Supports a maximum of 4,000 Logix-based alarms
(1)
.
• Ethernet communication that supports Device Level Ring (DLR), linear,
or star network topologies.
• High-speed human machine interface (HMI) button control and easily
configured navigation menu.
Topic
Page
Topic
Page
About the PanelView 5510 Terminals
Typical Configuration
Ethernet Cables
(1) PanelView 5510 firmware can support up to 4,000 Logix-based alarms if you use Studio 5000 View Designer application version 5
and Studio 5000 Logix Designer application version 32 or higher. Earlier versions of the Studio 5000 View Designer or Studio 5000
Logix Designer applications can support up to 1,000 Logix-based alarms. For more information about the Logic-based alarms, see
footnote 2.
(2) A combination of up to four of the following Logix controller models: ControlLogix L7 or CompactLogix L1, L2, or L3 controller with
revision 31 firmware or later.
NOTE: If the PanelView 5510 terminal supports up to four Logix controllers, then each controller can use a mix (instruction-based
and tag-based) of alarms up to 1,000 alarms per controller. If a single Logix controller is supported, then up to 4,000 alarms can be
used but only 1,000 of them can be instruction-based.
Содержание Allen-Bradley PanelView 5510 Series
Страница 6: ...6 Rockwell Automation Publication 2715P UM001C EN P March 2019 Table of Contents Notes...
Страница 10: ...10 Rockwell Automation Publication 2715P UM001C EN P March 2019 Preface Notes...
Страница 86: ...86 Rockwell Automation Publication 2715P UM001C EN P March 2019 Chapter 5 Install and Replace Components Notes...
Страница 92: ...92 Rockwell Automation Publication 2715P UM001C EN P March 2019 Chapter 6 Update Firmware Notes...
Страница 108: ...108 Rockwell Automation Publication 2715P UM001C EN P March 2019 Index Notes...
Страница 109: ...Rockwell Automation Publication 2715P UM001C EN P March 2019 109 Index Notes...
Страница 110: ...110 Rockwell Automation Publication 2715P UM001C EN P March 2019 Index Notes...
Страница 111: ......