Use of Motors

Servo motors are intended to drive machinery. As such, they must be part of a controlled system that 
includes a transistorized electronic amplifier. They are not intended for direct connection to the power 
supply or for use with thyristor drives. Instructions in the amplifier and control system manuals must 
be observed; this document does not replace those instructions.

Unless specified otherwise, servo motors are intended for use in a normal industrial environment 
without exposure to excessive or corrosive moisture or abnormal ambient temperatures. The exact 
operating conditions may be established by referring to the data for the motor. The mating of motors 
to machinery is a skilled operation; disassembly or repair must not be attempted. In the event that a 
motor fails to operate correctly, contact the place of purchase for return instructions.

Safety Notes

There are some possible hazards associated with the use of motors. The following precautions should 
be observed. Specific Warnings and Cautions are listed inside the back cover. 

Installation and Maintenance:

 Installation and maintenance or replacement must be carried out by 

suitably qualified service personnel, paying particular attention to possible electrical and mechanical 
hazards.

Weight:

 Large motors are generally heavy, and the center of gravity may be offset. When handling, 

take appropriate precautions and use suitable lifting equipment. Beware of sharp edges; use protec-
tive gloves when handling such assemblies.

Flying leads:

 Ensure that flying or loose leads are suitably restrained, to prevent snagging or entan-

glement, before carrying motors with such leads.

Generation:

 If the motor is driven mechanically, it may generate hazardous voltages at its power 

input terminals. The power connector must be suitably guarded to prevent a possible shock hazard.

Loose motors:

 When running an unmounted motor, ensure that the rotating shaft is adequately 

guarded and the motor is physically restrained to prevent it from moving. Remove the key which 
otherwise could fly out when the motor is running.

Damaged cables:

 Damage to cables or connectors may cause an electrical hazard. Ensure there is no 

damage before energizing the system.

Supply:

 Servo motors must not be directly connected to a power supply; they require an electronic 

drive system. Consult the instructions for the drive system before energizing or using the motor.

Brakes:

 The brakes that are included on motors are holding brakes only and are not to be used as a 

mechanical restraining device for safety purposes.

Safety requirements:

 The safe incorporation of this product into a machine system is the responsi-

bility of the machine designer, who should comply with the local safety requirements at the place 
where the machine is to be used. In Europe this is likely to be the Machinery Directive.

Mechanical connection:

 Motors must be connected to the machine with a torsionally rigid coupler 

or a reinforced timing belt. Couplers which are not rigid will cause difficulty in achieving an accept-
able response from the control system. Couplings and pulleys must be tight as the high dynamic 
performance of a servo motor can easily cause couplings to slip, and thereby damage the shaft and 
cause instability. Care must be taken in aligning couplings and tightening belts so that the motor is 
not subjected to significant bearing loads, or premature bearing wear will occur. Once connected to 
a load, tuning will be affected. A system tuned without a load will probably require retuning once a 
load is applied.

Connectors:

 Motor power connectors are for assembly purposes only. They should not be connected 

or disconnected while power is applied.

© 1999 Rockwell International Corporation. All rights reserved. 
Electro-Craft is a trademark of Rockwell Automation. 
Printed in the United States of America.
Information contained in this manual is subject to change without notice. 

Содержание Allen-Bradley N Series

Страница 1: ...N Series Brushless Servo Motor Manual Allen Bradley ...

Страница 2: ...se motors When running an unmounted motor ensure that the rotating shaft is adequately guarded and the motor is physically restrained to prevent it from moving Remove the key which otherwise could fly out when the motor is running Damaged cables Damage to cables or connectors may cause an electrical hazard Ensure there is no damage before energizing the system Supply Servo motors must not be direc...

Страница 3: ...2 9 Thermal Resistance o C Watt 3 0 2 2 1 6 1 2 1 1 0 83 Dielectric Rating Power Leads R S T to Ground 1800 VACrms 50 60 Hz for 1 minute MOTOR N 5630 2 N 5637 2 N 5647 2 MECHANICAL DATA 1 Rotor Moment of Inertia kg m2 0 0009 0 0012 0 0015 lb in s2 0 008 0 01 0 013 Rotor Moment of Inertia Motors W Brake kg m2 0 000651 0 000778 0 000893 lb in s2 0 00576 0 00689 0 00791 Motor Weight Net kg lb 9 1 20 ...

Страница 4: ... DIA CIRCLE P AK power connector brake option connector SHAFT END PLAY UNDER LOAD Maximum end play All Motors Direction mm in Load Kg Lb A 0 127 0 005 3 8 10 B 0 025 0 001 Note End play and load are measured in inches and pounds Metric measurements are approxi mate conversions from inches and pounds N 3400 N 4200 N 5600 N 2300 ...

Страница 5: ...0 0 39 7 0 28 174 6 85 219 8 63 4 8 X 4 8 0 1875 X 0 1875 5 16 63 3 24 0 94 6 N 4220 199 7 85 245 9 63 N 5630 75 2 96 50 1 97 1 149 5 88 114 4 50 8 12 0 47 0 375 in UNC 199 7 83 256 10 06 19 75 3 38 1 50 6 N 5637 224 8 83 281 11 06 N 5647 250 9 83 306 12 06 NOTE Motors are manufactured to inch dimensions Millimeter dimensions are approximate conversions from inches SUPPLEMENTAL MOTOR DIMENSIONS Le...

Страница 6: ...5 VDC N 4200 K 5 VDC L COMMON N 5600 L COMMON M COMMON Connectors require1 4 turn to seal M COMMON N Open N Open P Open Brake Connector P Ns P Open R THERMOSTAT N 2300 KPSE02E12 3P A71 R THERMOSTAT S THERMOSTAT N 3400 S THERMOSTAT T HALL A N 4200 T HALL A U HALL B N 5600 U HALL B V HALL C Connectors require1 4 turn to seal V HALL C NEMA 23 Series Power Connector Brake Option Connector NEMA 34 42 5...

Страница 7: ...LL signals Logic 1 3 5 VDC min 1mA DC source Logic 0 0 5 VDC max 5mA DC sink Index Pulse Refer to diagrams below No key for physical reference When facing the motor the key is oriented 90o 10 clockwise mechanical from connectors 1 Standard line count before quadrature 2 N 2300 encoder does not have Absolute Signal ABS A A B B I I Logic 1 Logic 0 90o 45o Index Alignment Reference 360o 2 5 VDC min 0...

Страница 8: ...Encoder Phase to Neutral and Phase to Phase Waveforms NOTE N 3400 N 4200 and N 5600 only NOTE Hall and ABS signals are in electrical degrees For 4 pole commutation 360 mechanical 720 electrical ...

Страница 9: ... dimensions are conversions from inches Shaft seals require a lubricant to reduce wear Lubricant is provided with kit MOTOR POWER CONNECTORS PART NUMBER CONNECTOR TYPE 9101 1557 POWER SOLDER 9101 1558 ENCODER SOLDER 9101 1698 BRAKE SOLDER These connectors provide environmental sealing and shield termination OTHER MATING CONNECTORS STRAIGHT CONNECTOR TYPE RIGHT ANGLE MS3126F14 19S ENCODER CRIMP KPS...

Страница 10: ...h that is potentially damaging to the system increases brake pad wear and reduces brake life The brakes are not designed nor are they intended to be used as a safety device A separate power source is required to disengage the brake This power source may be controlled by the servo motor controls in addition to manual operator controls Brake Specifications STANDARD RADIAL LOAD FORCE RATINGS 500 rpm ...

Страница 11: ...ystem electromagnetic com patibility EMC General cable build and installation guidelines include 1 Keep wire lengths as short as physically possible 2 Route signal cables encoder serial analog away from motor and power wiring 3 Separate cables by 1 foot minimum for every 30 feet of parallel run 4 Ground both ends of the encoder cable and twist the signal wire pairs 5 Use shielded motor cables when...

Страница 12: ...ng your supplier Please contact the source that supplied the motor for warranty non warranty or disposal work All returned products require a Return Material Authorization RMA number for efficient processing and tracking For more information refer to our web site www ab com motion FACTORY DESIGNATED SPECIAL OPTIONS AA STANDARD FLANGE OPTIONS 00 STANDARD 04 24 VDC BRAKE ENCODER LINE COUNT F 1000 N ...