Troubleshooting the Drive
Common Symptoms and
Corrective Actions
through
Table 30
describe common symptoms and corrective actions.
Table 24 - Drive Does Not Start From Start, Run, or Jog Inputs Wired to the Terminal Block
Table 25 - Drive Does Not Start or Jog From OIM
Indication(s)
Cause(s)
Corrective Action
Flashing red Ready LED.
Drive is faulted.
Clear fault:
• Press OIM stop key. This action only succeeds if the clear faults function for
that OIM is enabled using the Logic Mask (276) and Fault Clr Mask (283).
• Cycle power.
• Set Fault Clear (240) to 1.
• Toggle terminal block stop or terminal block fault reset digital input. This
action only succeeds if the clear faults function for that OIM is enabled using
the Logic Mask (276) and Fault Clr Mask (283).
• Cycle power.
Incorrect operation from the terminal
block.
Incorrect input wiring.
• 2-wire control requires Run, Run Forward, or Run
Reverse input(s).
• 3-wire control requires Start and Stop inputs
• Jumper from terminal 7 to 8 is required.
Wire inputs correctly and/or install jumper.
Incorrect digital input programming.
• Mutually exclusive choices have been made.
• 2-wire and 3-wire programming may be
conflicting.
• Exclusive functions (for example, direction control)
may have multiple inputs configured.
• Stop if factory default and is not wired or is open.
• Start or Run programming may be missing.
Program Digital In
x
Sel (361...366) for correct inputs.
The Digital In bit of one or more of the mask
parameters (276...285) is not set.
Set the Digital In bit to 1 in the appropriate mask parameters (276...285). The
Digital In bit of the Logic Mask (276) must be set if any control function is to be
performed from the terminal block.
Flashing yellow Ready LED and DigIn
CflctB indication on OIM.
Drive Status 2 (210) shows type 2
alarm(s).
Incorrect digital input programming.
• Mutually exclusive choices have been made.
• 2-wire and 3-wire programming may be
conflicting.
• Exclusive functions (i.e, direction control) may have
multiple inputs configured.
• Stop if factory default and is not wired or is open.
• Start or Run programming may be missing.
Program Digital In
x
Sel (361...366) to resolve conflicts.
Remove multiple selections for the same function.
Install stop button to apply a signal at stop terminal.
Indication
Cause(s)
Corrective Action
None
Drive is programmed for 2-wire control, and the bits
of the Logic Mask (276) and Start Mask (277) that
apply to the OIM are set to 1.
If 2-wire control is required, no action is necessary.
If 3-wire control is required, program Digital In
x
Sel (361...366) for correct inputs.
Flashing or steady red Ready LED.
Active fault.
Reset fault.
Flashing yellow Ready LED.
Enable input is open.
Close terminal block enable input.
The terminal block stop input is open.
Close terminal block stop input.
Start inhibit bits are set.
Check status in Start Inhibits (214).
Содержание Allen-Bradley LiquiFlo 2.0
Страница 1: ...LiquiFlo 2 0 AC Drive User Manual OriginalInstructions ...
Страница 6: ...6 Rockwell Automation Publication D2 3518 4 January 2020 Table of Contents Notes ...
Страница 8: ...8 Rockwell Automation Publication D2 3518 4 January 2020 Preface Notes ...
Страница 12: ...12 Rockwell Automation Publication D2 3518 4 January 2020 Chapter 1 Introduction Notes ...
Страница 34: ...34 Rockwell Automation Publication D2 3518 4 January 2020 Chapter 2 About the Drive Notes ...
Страница 44: ...44 Rockwell Automation Publication D2 3518 4 January 2020 Chapter 3 Planning the Installation Notes ...
Страница 68: ...68 Rockwell Automation Publication D2 3518 4 January 2020 Chapter 8 Programming Basics Notes ...
Страница 190: ...190 Rockwell Automation Publication D2 3518 4 January 2020 Chapter 9 Parameter Descriptions Notes ...
Страница 228: ...228 Rockwell Automation Publication D2 3518 4 January 2020 Chapter 10 Troubleshooting the Drive Notes ...
Страница 250: ...250 Rockwell Automation Publication D2 3518 4 January 2020 Appendix A LiquiFlo 2 0 Drive Frame 3Wiring Diagrams Notes ...
Страница 258: ...258 Rockwell Automation Publication D2 3518 4 January 2020 Appendix B LiquiFlo 2 0 Drive Frame 4Wiring Diagrams Notes ...
Страница 267: ......