6
Rockwell Automation Publication KNX-RM007A-EN-P - October 2021
Kinetix 7000 Drive System Design Guide
Kinetix 7000 AC Input Power Example (with regenerative power)
In this example, the Kinetix 7000 drive system is shown with the 8720MC Regenerative Power Supply (RPS) in DC common-bus configuration
with two follower Kinetix 7000 drives. Harmonic filter and varistor are available separately, but are included with the RPS unit when ordering
catalog number 8720MC-RPS065-BM-HV2.
In this full-line regenerative example, the 8720MC-RPS065 unit provides motoring power and regenerative braking.
IMPORTANT
Regenerative braking applications are limited to only one Kinetix 7000 common-bus follower drive.
1606-XL
Power Supply
Input
Allen-Bradley
REG ENERATIV E P O W ER S UPPLY
8720
8720
MC
MC
RST PRG
ENT
READY
READY
FAULT
FAULT
PROGRAM
PROGRAM
kW
kW
V
A
DC Bus
Regenerative Power Supply
8720MC-RPS065-BM-HV2
Common Bus Leader
Line Reactor
8720MC-LR
xx
Three-phase
Input Power
Varistor (8720MC-VA-B)
Included with
8720MC-RPS065-BM-HV2.
Harmonic Filter (8720MC-HF-B2)
Included with
8720MC-RPS065-BM-HV2.
Magnetic
Contactor
24V DC
Control Power
1606-XL
xxx
AC Line Filter 8720MC-RFI80
(required for CE)
Input
Fusing
Three-phase
Input Power
Magnetic
Contactor
Input
Fusing
Line Reactor
8720MC-LR
xx
Regenerative
Power Only
Kinetix 7000 Drive
2099-BM
xx
-S
Common Bus Follower
Control Power
Supply Input
AC Line Filter
2090-XXLF-TC
xxxx
(required for CE)
Kinetix HPK, MMA, and RDB Motors