126
Rockwell Automation Publication 5069-UM003B-EN-P - January 2020
Appendix A
Module Tags
Input Tags
Output Tags
Table 34 - DF1 Master Input Tags
Name
Data Type
Definition
Valid Values
I
x
.DF1.RunMode
BOOL
Channel’s operating state
• 0 = Idle
• 1 = Run
I
x
.DF1.ConnectionFaulted
BOOL
Indicates if a connection is running.
The module sets this tag to 0 when connected. If the module is not
connected, it changes the tag to 1.
• 0 = Connection running
• 1 = Connection not running
I
x
.DF1.DiagnosticActive
BOOL
Indicates if any diagnostics are active or if the prognostics threshold
is reached.
• 0 = No diagnostics active
• 1 = One or more diagnostics are active or the
prognostics threshold is reached
I
x
.DF1.DiagnosticSequenceCount
SINT
Increments for each time a distinct diagnostic condition is detected,
and when a distinct diagnostic condition transitions from detected
to not detected.
Set to zero by product reset or power cycle. Wraps from 255 (-1) to 1
skipping zero.
• -128…+127
The value of 0 is skipped except during module
power-up.
I
x
.DF1.CTS
BOOL
Indicates whether the CTS is active.
• 0 = Inactive
• 1 = Active
I
x
.DF1.RTS
BOOL
Indicates whether the RTS is active.
• 0 = Inactive
• 1 = Active
I
x
.DF1.DSR
BOOL
Indicates whether the DSR is active.
• 0 = Inactive
• 1 = Active
I
x
.DF1.DCD
BOOL
Indicates whether the DCD is active.
• 0 = Inactive
• 1 = Active
I
x
.DF1.DTR
BOOL
Indicates whether the DTR is active.
• 0 = Inactive
• 1 = Active
I
x
.DF1.MsgProcessing
BOOL
Determine if instruction message is processing.
• 0 = Not Processing
• 1 = Processing
I
x
.DF1Master.ActiveStation
SINT (32)
Determine if station is active.
• 0 = Inactive
• 1 = Active
I
x
.DF1Master.PriorityPollError
BOOL
Shows if there was a priority polling error.
• 0 = Non-occurrence
• 1 = Occurrence
I
x
.DF1Master.NormalPollError
BOOL
Shows if there was a normal polling error.
• 0 = Non-occurrence
• 1 = Occurrence
I
x
.DF1Master.PollGroupSizeError
BOOL
Shows if the Normal Poll Group size is greater than the Max Normal
Poll Node.
• 0 = Non-occurrence
• 1 = Occurrence
I
x
.DF1Master.LatestPriorityPollNode
INT
Address of Priority Poll Node currently being polled.
• -32768…+32767
I
x
.DF1Master.LatestNormalPollNode
INT
Address of Normal Poll Node currently being polled.
• -32768…+32767
Table 35 - DF1 Master Output Tags
Name
Data Type
Definition
Valid Values
O
x
.DF1Master.MaxPriorityPollNode
INT
Defines the maximum number of nodes in the Priority Poll Node.
• -32768…+32767
O
x
.DF1Master.MaxNormalPollNode INT
Defines the maximum number of nodes in the Normal Poll Node.
• -32768…+32767
O
x
.DF1Master.PollingListUpdateID
SINT
This ID is incremented when you want to update the polling list in the serial module.
• -128…+127
Ox.DF1Master.PriorityPollNode
(1)
INT[N]
Defines the poll sequence the DF1 Master polls for priority node.
–
Ox.DF1Master.NormalPollNode
(1)
INT[M]
Defines the poll sequence the DF1 Master polls for normal node.
–
(1) If you configure the polling in the module definition, there will be two more tag array generated. The array is dynamically generated depending on what you configure in the definition.
Содержание Allen-Bradley 5069-L3100ERMS2
Страница 1: ...Compact 5000 I O Serial Module Catalog Numbers 5069 SERIAL User Manual OriginalInstructions ...
Страница 130: ...130 Rockwell Automation Publication 5069 UM003B EN P January 2020 Appendix A ModuleTags Notes ...
Страница 143: ...Rockwell Automation Publication 5069 UM003B EN P January 2020 143 Programming Example Appendix C ...
Страница 146: ...146 Rockwell Automation Publication 5069 UM003B EN P January 2020 Appendix C Programming Example ...
Страница 155: ......