68
Rockwell Automation Publication 2094-UM001D-EN-P - May 2010
Chapter 4
Kinetix 6000 Connector Data
Table 33 - Brake Relay Output Specifications
Input Power Cycle Capability
The power cycle capability is inversely proportional to the system capacitance
(including DC bus follower), but cannot exceed 2 contactor cycles per minute
with up to 4 axes or 1 contactor cycle per minute with 5…8 axes.
The cycle capability also depends on the converter power rating and the total
system capacitance. Refer to Appendix D on
to calculate total system
capacitance.
Table 34 - Maximum Input Power Cycling Specifications (230V)
Table 35 - Maximum Input Power Cycling Specifications (460V)
For example, in a 4 axis system with a 2094-BC02-M02-S IAM module and
2,000 μF total capacitance, the calculated capability is 0.52 x 10,000/2000 = 2.6
cycles per minute. However, this value is reduced to 2.0 by the 4 axes per system
limitation.
Attribute
Description
IAM/AM Module
Value, Max
Series A
Value, Max
Series B
On-state current
(1)
Current flow when the
relay is closed
2094-AC05-M
xx
,-
x
2094-AC09-M02-
x
,
2094-AMP5-
x
, 2094-AM01-
x
, 2094-AM02-
x
1.0 A
N/A
2094-BC01-M
xx
-
x
, 2094-BC02-M02-
x
,
2094-BMP5-
x
, 2094-BM01-
x
, 2094-BM02-
x
3.0 A
2094-AC16-M03-
x
, 2094-AC32-M05-
x
,
2094-AM03-
x
, 2094-AM05-
x
1.3 A
N/A
2094-BC04-M03-
x
, 2094-BC07-M05-
x
,
2094-BM03-
x
, 2094-BM05-
x
3.0 A
3.0 A
On-state resistance
Contact resistance when the relay is closed
1
Ω
1
Ω
Off-state voltage
Voltage across the contacts when the relay is open
30V
30V
(1) For motors requiring more than the maximum current specified, a relay must be added.
Attribute
2094-AC05-MP5-S
2094-AC05-M01-S
2094-AC09-M02-S
2094-AC16-M03-S
2094-AC32-M05-S
Main AC input power cycling
(cycles per minute for 10,000 µf)
0.69
4.30
Attribute
2094-BC01-MP5-S
2094-BC01-M01-S
2094-BC02-M02-S
2094-BC04-M03-S
2094-BC07-M05-S
Main AC input power cycling
(cycles per minute for 10,000 µf)
0.12
0.52
2.15
4.30
Содержание Allen-Bradley 2094-BC01-M01-S
Страница 4: ...4 Rockwell Automation Publication 2094 UM001D EN P May 2010 Summary of Changes Notes...
Страница 10: ...10 Rockwell Automation Publication 2094 UM001D EN P May 2010 Table of Contents Notes...
Страница 126: ...126 Rockwell Automation Publication 2094 UM001D EN P May 2010 Chapter 5 Connecting the Kinetix 6000 Drive System Notes...
Страница 228: ...228 Rockwell Automation Publication 2094 UM001D EN P May 2010 Appendix B Interconnect Diagrams Notes...
Страница 270: ...270 Rockwell Automation Publication 2094 UM001D EN P May 2010 Appendix F RBM Module Interconnect Diagrams Notes...
Страница 278: ...278 Rockwell Automation Publication 2094 UM001D EN P May 2010 Index Notes...
Страница 279: ......