180
Rockwell Automation Publication 2094-UM001D-EN-P - May 2010
Appendix A
Specifications and Dimensions
Power Specifications
This section contains power specifications for your Kinetix 6000 system
components.
Integrated Axis Module (converter) Power Specifications
Table 96 - IAM Module (230V) Power Specifications
Attribute
2094-AC05-MP5-
x
2094-AC05-M01-
x
2094-AC09-M02-
x
2094-AC16-M03-
x
2094-AC32-M05-
x
AC input voltage
195…264V rms
three-phase (230V nom)
AC input frequency
47…63 Hz
Main AC input current
Nom (rms)
Max inrush (0-pk)
(1)
10 A
19 A
19 A
37 A
36 A
73 A
71 A
138 A
DC input voltage
(common-bus follower)
275…375V DC
DC input current
(common-bus follower)
10 A
19 A
36 A
71 A
Control power AC input voltage
95…264V rms
single-phase (230V nom)
Control power AC input current
Nom (@ 220/230V AC) rms
Nom (@ 110/115V AC) rms
Max inrush (0-pk)
3 A
6 A
20 A
3 A
6 A
83 A
(2)
Nominal bus output voltage
325V DC
Line loss ride through
20 ms
Continuous output current
to bus (A
dc
)
10 A
19 A
36 A
71 A
Peak output current
to bus (A
dc
)
(3)
20 A
38 A
72 A
142 A
Bus overvoltage
415V DC
Bus undervoltage
138V DC
Internal shunt
Continuous power
Peak power
N/A
N/A
50 W
8200 W
200 W
5700 W
200 W
5700 W
Internal shunt resistor
N/A
20
Ω
28.75
Ω
28.75
Ω
Shunt on
N/A
405V DC
Shunt off
N/A
375V DC
Continuous power output to bus
3 kW
6 kW
11.3 kW
22.5 kW
Peak power output
6 kW
12 kW
22.6 kW
45.0 kW
Efficiency
95%
Converter inductance
N/A
150
μ
H
75
μ
H
Converter capacitance
270
μ
F
540
μ
F
1320
μ
F
1980
μ
F
Short circuit current rating
200,000 A (rms) symmetrical
(1) All IAM modules are limited to 2 contactor cycles per minute (with up to 4 axes), or 1 contactor cycle per minute (with 5…8 axes). The cycle capability also depends on the
converter power rating and the total system capacitance. Refer to Input Power Cycle Capability on
, when making calculations.
(2) Maximum inrush duration is less than 1/2 line cycle.
(3) Peak output current duration equals 250 ms.
Содержание Allen-Bradley 2094-BC01-M01-S
Страница 4: ...4 Rockwell Automation Publication 2094 UM001D EN P May 2010 Summary of Changes Notes...
Страница 10: ...10 Rockwell Automation Publication 2094 UM001D EN P May 2010 Table of Contents Notes...
Страница 126: ...126 Rockwell Automation Publication 2094 UM001D EN P May 2010 Chapter 5 Connecting the Kinetix 6000 Drive System Notes...
Страница 228: ...228 Rockwell Automation Publication 2094 UM001D EN P May 2010 Appendix B Interconnect Diagrams Notes...
Страница 270: ...270 Rockwell Automation Publication 2094 UM001D EN P May 2010 Appendix F RBM Module Interconnect Diagrams Notes...
Страница 278: ...278 Rockwell Automation Publication 2094 UM001D EN P May 2010 Index Notes...
Страница 279: ......